Hitachi RAS-25JX4 Service Manual page 89

Room air conditioner
Hide thumbs Also See for RAS-25JX4:
Table of Contents

Advertisement

OUTDOO UNIT
emove the compressor connector.
IPM
INTELLIGENT
POWER MODULE
SELF DIAGNOSIS LAMPS
If your first attempt
fails, wait 3 minutes
(for the unit to re-
start) and check the
self-diagnosis lamp
status again.
LD301
LD302
LD303
With the unit set in the operating
state, press the start/stop
button.
Does the unit operate for
approximately 2 seconds (the
LD303 coming on) and then
stop due to a failure of switching
(the lamp blinking 4 times)?
Check outdoor electrical parts.
SERVICE SWITCH
Yes
No
94
¥ Check the drive
circuit (IMP) using
the PRD checker.
¥ Check the position
sensor circuit.
Normal
Check the refrigerating
cycle.