17" LCD Color Monitor
•
Un-package test
Sine vibration (operating)
Half sine shock test (non operation)
5.16 Pallet / Container loading
Transportation standards refer to TYE-M0002.
• Air shipment -
• Sea container 20'(pallet/slip sheet) -
• Sea container 40'(pallet/slip sheet) -
•
Sea container 40' High Cube (pallet/slip sheet) -
•
Truck shipment-
A.
Container loading for Air
B.
Container loading for all regions except China. India for Sea
C.
Container loading for China. India for Sea
D.
Truck loading for other regions
6. Environmental characteristics
The following sections define the interference and susceptibility condition limits that might occur between external
environment and the display device.
6.1 Susceptibility of display to external environment
Operating
- Temperature : 0 to 35 degree C
- Humidity
: 80% max
- Altitude
: 0-3658m
- Air pressure
: 600-1100 mBAR
Storage
- Temperature
: -20 to +60 degree C
- Humidity
: 85% max ( < 40℃ )
- Altitude
: 0-12192m
- Air pressure
: 300-1100 mBAR
6.2 Display disturbances from external environment
According to IEC 801-2 for ESD disturbances
6.3 Display disturbances to external environment
Refer to Safety requirement
7. Reliability
7.1 Mean Time Between Failure
System MTBF (Excluding the LCD panel and CCFL) : 50,000 hrs
8. Quality assurance requirements
8.1 Acceptance test
According to MIL-STD-105D
AQL: 0.4 (major)
(Please also refer to annual quality agreement)
Note: recommend at 5 to 35°C, Humidity less than 60 %
Control II level
1.5 (minor)
See below B, C.
See below D.
93
See below A.
See below B, C.
See below B, C.