9
A
Unit combination
Å Outdoor model
unit 1
unit 2
P200
-
-
P250
-
-
P300
-
-
P350
-
-
P400
-
-
P450
-
-
P500
P250
P250
P550
P300
P250
P600
P350
P250
P350
P300
P650
P350
P350
P700
P750
P400
P350
P450
P350
P800
P450
P400
P850
P450
P450
P900
P400
P300
P950
P400
P300
P1000
P400
P350
P1050
P400
P350
P1100
P450
P350
P1150
P1200
P450
P400
P450
P450
P1250
-
-
EP200
EP300
-
-
EP400
EP200
EP200
EP450
P250
EP200
EP500
EP300
EP200
EP550
EP300
P250
EP600
EP300
EP300
EP650
P350
EP300
EP700
EP300
EP200
EP750
EP300
P250
EP800
EP300
EP300
EP850
EP300
EP300
EP900
EP300
EP300
*1 ø12.7 for over 90m
*2 ø12.7 for over 40m
*3 The pipe sizes listed in columns A1 to A3 in this table correspond to the
sizes for the models listed in the unit 1, 2, and 3 columns. When the order
of the models for unit 1, 2, and 3 change, make sure to use the appropriate
pipe size.
B, C, D
Î Total capacity of indoor units
~ 140
141 ~ 200
201 ~ 300
301 ~ 400
401 ~ 650
651 ~ 800
801 ~
a, b, c, d, e
‰ Model number
ı Liquid pipe
20,25,32,40,50
63,71,80,100,125,140
200
250
Ï Downstream unit model total
~ 200
201 ~ 400
401 ~ 650
Ó The 1st branch of P450 ~ P650
651 ~
È The 1st branch of P700, P750, P800
4
A
ı Liquid pipe
Ç Gas pipe
unit 3
-
ø9.52
ø19.05
-
*1 ø9.52
ø22.2
-
*2 ø9.52
ø22.2
-
ø12.7
ø28.58
-
ø12.7
ø28.58
-
ø15.88
ø28.58
-
ø15.88
ø28.58
-
ø15.88
ø28.58
-
ø15.88
ø28.58
-
ø15.88
ø28.58
-
ø19.05
ø34.93
-
ø19.05
ø34.93
-
ø19.05
ø34.93
-
ø19.05
ø41.28
-
ø19.05
ø41.28
P250
ø19.05
ø41.28
P300
ø19.05
ø41.28
P300
ø19.05
ø41.28
P350
ø19.05
ø41.28
P350
ø19.05
ø41.28
P350
ø19.05
ø41.28
P350
ø19.05
ø41.28
-
ø9.52
ø19.05
-
*2 ø9.52
ø22.2
-
ø12.7
ø28.58
-
ø15.88
ø28.58
-
ø15.88
ø28.58
-
ø15.88
ø28.58
-
ø15.88
ø28.58
-
ø15.88
ø28.58
EP200
ø19.05
ø34.93
EP200
ø19.05
ø34.93
EP200
ø19.05
ø34.93
P250
ø19.05
ø41.28
EP300
ø19.05
ø41.28
ı Liquid pipe
Ç Gas pipe
ø9.52
ø15.88
ø9.52
ø19.05
ø9.52
ø22.2
ø12.7
ø28.58
ø15.88
ø28.58
ø19.05
ø34.93
ø19.05
ø41.28
Ç Gas pipe
ø6.35
ø12.7
ø9.52
ø15.88
ø9.52
ø19.05
ø9.52
ø22.2
Ì Joint
CMY-Y102S-G2
CMY-Y102L-G2
CMY-Y202-G2
CMY-Y302-G2
9.2
A1 *3
A2 *3
ı Liquid pipe
Ç Gas pipe
ı Liquid pipe
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ø9.52
ø22.2
ø9.52
ø12.7
ø22.2
ø9.52
ø12.7
ø28.58
ø9.52
ø12.7
ø28.58
ø12.7
ø12.7
ø28.58
ø12.7
ø15.88
ø28.58
ø12.7
ø15.88
ø28.58
ø12.7
ø15.88
ø28.58
ø15.88
ø15.88
ø28.58
ø15.88
ø15.88
ø28.58
ø12.7
ø15.88
ø28.58
ø12.7
ø15.88
ø28.58
ø12.7
ø15.88
ø28.58
ø12.7
ø15.88
ø28.58
ø12.7
ø15.88
ø28.58
ø15.88
ø15.88
ø28.58
ø15.88
-
-
-
-
-
-
ø9.52
ø22.2
ø9.52
ø9.52
ø22.2
ø9.52
ø12.7
ø22.2
ø9.52
ø12.7
ø22.2
ø9.52
ø12.7
ø22.2
ø12.7
ø12.7
ø28.58
ø12.7
ø12.7
ø22.2
ø9.52
ø12.7
ø22.2
ø9.52
ø12.7
ø22.2
ø12.7
ø12.7
ø22.2
ø12.7
ø12.7
ø22.2
ø12.7
(mm)
(mm)
Ô 4-Branching header
(Downstream unit
< =
model total
200)
CMY-Y104-G
Å Outdoor model
P500 ~ P650
EP400 ~ EP650
P700 ~ P900
P950 ~ P1250
EP700 ~ EP900
A3 *3
Ç Gas pipe
ı Liquid pipe
Ç Gas pipe
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ø22.2
-
-
ø22.2
-
-
ø22.2
-
-
ø22.2
-
-
ø28.58
-
-
ø28.58
-
-
ø28.58
-
-
ø28.58
-
-
ø28.58
-
-
ø22.2
ø9.52
ø22.2
ø22.2
ø12.7
ø22.2
ø28.58
ø12.7
ø28.58
ø28.58
ø12.7
ø28.58
ø28.58
ø12.7
ø28.58
ø28.58
ø12.7
ø28.58
ø28.58
ø12.7
ø28.58
-
-
-
-
-
-
ø22.2
-
-
ø22.2
-
-
ø22.2
-
-
ø22.2
-
-
ø22.2
-
-
ø22.2
-
-
ø22.2
ø9.52
ø22.2
ø22.2
ø9.52
ø22.2
ø22.2
ø9.52
ø22.2
ø22.2
ø9.52
ø22.2
ø22.2
ø12.7
ø22.2
Ò 10-Branching header
8-Branching header
(Downstream unit
(Downstream unit
< =
model total
400)
model total
CMY-Y108-G
˜ Outdoor twinning kit
CMY-Y100VBK2
CMY-Y200VBK2
CMY-Y300VBK2
(mm)
A4
ı Liquid pipe
Ç Gas pipe
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ø19.05
ø34.93
ø19.05
ø34.93
ø19.05
ø34.93
ø19.05
ø34.93
ø19.05
ø34.93
ø19.05
ø34.93
ø19.05
ø34.93
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ø19.05
ø34.93
ø19.05
ø34.93
ø19.05
ø34.93
ø19.05
ø34.93
ø19.05
ø34.93
< =
650)