1.
Measurement Conditions
1-1
Environment
• Temperature: From 5 °C to 40 °C.
• Humidity: From 30 % to 90 %.
1-2
Power Source
The voltage is within ±10 %. AC adaptor PA-30 should be used.
• U
: 120 V
(WE524200)
• H
: 230 V
(WE523900)
• B
: 230 V
(WE523700)
• A
: 240 V
(WE523600)
• K
: 220 V
(WE524100)
• O
: 220 V
(WE523800)
1-3
Application software of USB AUDIO
Use an application software that can be set as follows.
Sampling rate
Resolution
2.
Mixer Check
2-1
Preparation
• The load resistances for each output terminals are as follows:
PHONES (L/R)
ST OUT
Others
2-2
Unless otherwise specified, the controls should be set as follows:
• CH INPUT (1-12)
GAIN control
80 switch
COMP control (1-8)
EQ (HIGH, MID, LOW) GAIN control
EQ MID frequency control
AUX1, AUX2, AUX3, AUX4 level control
AUX2, AUX3 PRE switch
PAN control
ON switch
PFL switch
1-2, 3-4 switch
ST switch
Channel fader
• ST INPUT (13/14-19/20)
GAIN control
80
EQ (HIGH, MID, LOW) GAIN control
AUX1, AUX2, AUX3, AUX4 level control
AUX2, AUX3 PRE switch
PAN/BAL control
ON switch
PFL switch
: 48 kHz or 44.1 kHz
: 16 bits
: 40 Ω (=3 W or more than 3 W)
: 600 Ω
: 10 kΩ
Maximum (-60/-34 dBu)
OFF
Minimum
CENTER
Minimum
Maximum
OFF (POST)
L (turned counterclockwise fully)
ON (indicator should light) when taking measurement only /
OFF otherwise
ON when taking measurement only / OFF otherwise
ON when taking measurement only / OFF otherwise
ON when taking measurement only / OFF otherwise
Maximum
Maximum (-60/-34 dBu)
OFF
CENTER
Maximum
OFF (POST)
L (turned counterclockwise fully)
ON (indicator should light) when taking measurement only /
OFF otherwise
ON when taking measurement only / OFF otherwise