To obtain high and low voltage readings with the North Star 10000 PPG generator:
- High Voltage Reading: Measure the voltage when the generator is running with no loads connected. According to the Load vs. Output chart, at 0% load, the generator runs at 3750 RPM, 62.5 Hz, and outputs about 129V at the 120V receptacle.
- Low Voltage Reading: Measure the voltage when the generator is fully loaded. At 100% load, the generator runs at 3600 RPM, 60.0 Hz, and outputs about 120V at the 120V receptacle.
Disconnect all loads before starting and connect loads after the engine is running properly.
This answer is automatically generated
Conners
February 17, 2025
Rubber gasket that fits in the bottom of gas tank that the shutoff valve fits inside it, need part number for the rubber gasket that is in the bottom of tank
Page 1
MODEL 10000 PPG, ITEM #165967 Professional Portable Generator M165967A P r o v e n P e r f o r m a n c e OWNER’S MANUAL Any Questions, Comments, or Problems? Call Customer Service at 1-800-270-0810 Hours: Monday - Friday 7:00 AM to 5:30 PM CST...
Thank you for purchasing a NorthStar Pro Series Generator. Your machine is designed for long life, dependability, and the top performance you demand. Please take time now to read through this manual so you can better understand the machine’s operation, maintenance and safety precautions.
GENERATOR FEATURES Reference 1 - Air Cleaner. Refer to your Honda Engine Owner’s Manual for air cleaner care. Reference 2 - Grounding Screw . generator via the grounding screw, to a copper pipe or rod that is driven into moist soil. Reference 3 - Circuit Breakers.
INTRODUCTION Before starting your generator, thoroughly study the instructions and cautions in this manual to assure you are fully acquainted with the operation of all components of this generator. Proper preparation, operation and maintenance will result in operator safety, best performance and long life of the generator. For detailed engine operation and maintenance always refer to the Vanguard engine owner’s manual furnished with the generator (Briggs and Stratton refer...
INSTALLATION OUTDOORS: Choose a location where the generator will not be exposed to rain, snow or direct sunlight. Position the generator on secure, level ground so it will not tip or slide down a hill. Place the generator so that the exhaust fumes will not be directed towards people.
Running the generator under these conditions may result in damage to the generator stator as well as the motor windings. Because the heavy surge of current is required for only an instant, the generator will not be damaged if it can bring the motor up to speed in a few seconds.
OPERATING SPEED The generator must be run at the correct speed in order to produce the proper electrical voltage and frequency. The speed of the engine was carefully adjusted at the factory so that the generator produces the proper voltage and frequency. The output voltage should be checked to ensure the generator is working properly before connecting a load to the generator.
GENERATOR CARE The generator head is a two pole, 3600 RPM, 60 Hz, brushless, revolving field and synchronous type with one sealed radial roller bearing. The rotor of the generator head is directly connected to the engine crankshaft and the stator is rigidly coupled to the engine casting via the generator head casting.
TROUBLESHOOTING Problem Possible Causes Engine will not start. a) Low oil level. b) Fouled spark plug. c) Out of fuel. d) Stop switch in OFF position. Voltage too low. a) Engine speed too slow. b) Generator is overloaded. Circuit breaker trips. a) Defective load connected to generator.
Need help?
Do you have a question about the 10000 PPG and is the answer not in the manual?
Questions and answers
In getting high and low voltage readings
To obtain high and low voltage readings with the North Star 10000 PPG generator:
- High Voltage Reading: Measure the voltage when the generator is running with no loads connected. According to the Load vs. Output chart, at 0% load, the generator runs at 3750 RPM, 62.5 Hz, and outputs about 129V at the 120V receptacle.
- Low Voltage Reading: Measure the voltage when the generator is fully loaded. At 100% load, the generator runs at 3600 RPM, 60.0 Hz, and outputs about 120V at the 120V receptacle.
Disconnect all loads before starting and connect loads after the engine is running properly.
This answer is automatically generated
Rubber gasket that fits in the bottom of gas tank that the shutoff valve fits inside it, need part number for the rubber gasket that is in the bottom of tank