7 - Ethernet Configuration Information

This unit comes pre-programmed to the following settings:
I.P. Address
Gateway
Netmask
Port
Important Note:
Open up a terminal session through your computer's COM port using a program like
HyperTerminal. You must use the Ethernet Configuration Cable to make the physical connection
from your COM port to the "Ethernet Config. Port" on the rear of the 50MS-192. The terminal
session should use the following COM port settings:
Baud Rate
Data Bits
Parity
Stop Bits
Flow Control None
You can verify a successful connection by typing "Hello World" in the terminal window. You
should receive an echo back from the 50MS-192. The SET commands listed below can then be
used to change the network properties.
SET IP xxx.xxx.xxx.xxx
SET NETMASK xxx.xxx.xxx.xxx
SET GATEWAY xxx.xxx.xxx.xxx
SET NAMESERVER xxx.xxx.xxx.xxx
192.168.1.225
192.168.1.1
255.255.255.0
3001 (hard-coded into the unit and can not be changed)
An additional document "Sample Ethernet Configuration Session for JFW
Model 50MS-192.PDF" comes with this manual and is located on the CD in
PDF format. This sample session shows step by step how the Ethernet port is
configured.
9600
8
None
1
Rev 0, 7-27-06
changes the I.P address
changes the Netmask
changes the Gateway
changes the Nameserver
Page - 7