6. Disconnect the couplers(P2, P9, P11, P12, P23, P25).
7. Remove the 6 screws and then remove the P-Board.
8. Disconnect the coupler(D20).
9. Remove the Flexible Cable from the couplers(D31, D32).
10. Remove the 4 screws and then remove the D-Board.
11. Remove the SU-Board and the SD-Board.
(Reference to Removal of the SU-Board and the SD-Board)
12. Remove the 6 screws and then remove the SC-Board.
13. Disconnect the couplers(SS23, SS34).
14. Remove the Flexible Cable from the couplers(SS41, SS42,
SS43, SS44).
15. Remove the 6 screws and then remove the SS-Board.
16. Remove the 6 screws and then remove the Flexible Cable
from the couplers(CB1, CB2, CB3, C12).
17. Remove the 3 screws and then remove the C1-Board.
18. Remove the 8 screws and then remove the Flexible Cable
from the couplers(CB4, CB5, CB6, CB7).
19. Remove the 4 screws and then remove the C2-Board.
20. Remove the 3 screws(H) and then remove the AC Inlet
Block.