q-Tech Q-P019 User Manual

q-Tech Q-P019 User Manual

Electric airless spray pump

Advertisement

Q-TECH
Q-P019 ELECTRIC AIRLESS SPRAY PUMP
USER MANUAL
CAUTION!
This manual contains
important warnings and information
PLEASE READ & KEEP FOR FUTURE REFERENCE
ISSUE DATE 31.05.2014

Advertisement

Table of Contents
loading

Summary of Contents for q-Tech Q-P019

  • Page 1 Q-TECH Q-P019 ELECTRIC AIRLESS SPRAY PUMP USER MANUAL CAUTION! This manual contains important warnings and information PLEASE READ & KEEP FOR FUTURE REFERENCE ISSUE DATE 31.05.2014...
  • Page 2: Specifications

    User Manual Q-Tech Q-P019 - Electric Airless Spray Pump SPECIFICATIONS Model Q-P019 Motor Type Universal Power input 700W Voltage 110-120V~ 50-60Hz , 220-240V~ 50-60Hz Max Tip Size 0.021” Max Flow 1.9 l/min (0.42 gpm) Max Pressure 207 bar (3,000 psi)
  • Page 3: Work Area

    www.aristospray.com GENERAL SAFETY RULES properly grounded. If the sprayer should electrically malfunction or break WARNING! Read and understand all down, grounding provides a low instructions. Failure to follow all resistance path to carry electricity instructions listed below may result in away from the user.
  • Page 4: Specific Safety Rules

    User Manual Q-Tech Q-P019 - Electric Airless Spray Pump d) Do not overreach. Keep a proper WARNING: FIRE AND EXPLOSION footing and balance at all times. This HAZARD. Take all precautions to avoid enables better control of the airless sources of sparks and ignition when sprayer in unexpected situations.
  • Page 5 www.aristospray.com PREVENT STATIC • ALWAYS lock the gun trigger when you stop spraying. SPARKING • ALWAYS remove tip from the gun to clean it. FIRE/EXPLOSIONS • NEVER try to "blow back" paint, this is not an air powered sprayer. Vapors created when spraying can be •...
  • Page 6 User Manual Q-Tech Q-P019 - Electric Airless Spray Pump • NEVER spray in vicinity of open flame TOXIC FLUID or other sources of ignition. HAZARD • The spraying area must be at least 20 ft. away from spray unit. •...
  • Page 7 www.aristospray.com • NEVER use a damaged hose, which grounding is obtained through can result in hose failure or rupture and connection to a properly grounded cause an injection injury or other fluid hose and pump. serious bodily injury or property 4.
  • Page 8: Operation

    User Manual Q-Tech Q-P019 - Electric Airless Spray Pump ASSEMBLY: procedure whenever the sprayer is shut off, when checking it, when installing, 1. Attach the hose to the pump and changing or cleaning tips and whenever tighten with a wrench.
  • Page 9: How To Flush

    www.aristospray.com 50/50 mixture of mineral spirits and properly grounded. Do not place motor oil. on a non conductive insulating surface unless a ground wire is CAUTION: Never leave water in the added to a true earth such as a pump for more than about a day. Flush metal water pipe.
  • Page 10 User Manual Q-Tech Q-P019 - Electric Airless Spray Pump 5. Allow the pump to run and watch the 3. 3. Thread the tip guard onto the gun fluid discharging from the drain tube. finger tight only. Allow the fluid to discharge until pure 4.
  • Page 11 www.aristospray.com have “tails”, which is a pattern with heavy, Trigger the gun before moving and release uneven edges. Keep testing and the trigger after each stroke. Overlap each increasing pressure until a smooth, regular previous stroke by half. Do this by aiming pattern is achieved.
  • Page 12: Spray Tip Selection

    User Manual Q-Tech Q-P019 - Electric Airless Spray Pump CLOGGED FLAT TIP tip identifies the fan width radius in inches. The last two numbers identify the orifice If you are using a flat tip and the spray tip size in thousandths of an inch. So, for...
  • Page 13 www.aristospray.com paint, cause overspray, make cutting-in run the pump. watch the material difficult, and decrease sprayer discharging from the drain tube until performance. the material begins to thin. This indicates that the flushing fluid is If the tip is the maximum rated size for beginning to pump out.
  • Page 14: Long Term Storage

    User Manual Q-Tech Q-P019 - Electric Airless Spray Pump 13. Without releasing the trigger, transfer 19. If flushing was with water, flush again the gun to the flushing bucket and with Q-Tector Pump Conditioner to allow the flushing fluid to recirculate for prevent corrosion inside the pump.
  • Page 15: Daily Maintenance

    www.aristospray.com DAILY MAINTENANCE the throat of the pump, and tightening the packing nut no longer helps, then the 1. Keep the displacement pump packings will require replacement. This is packing nut lubricated with Q-Lube best entrusted to a qualified repair Piston Lubricant at all times.
  • Page 16: Motor Maintenance

    User Manual Q-Tech Q-P019 - Electric Airless Spray Pump 6. Replace the packings, glands, o-rings THE CARBON BRUSHES and check balls with the new parts The carbon brushes are a normal wearing from the rebuild kit. Strictly follow the part and must be replaced when they exact order and orientation.
  • Page 17: Troubleshooting

    www.aristospray.com If the replacement of the power supply WARNING: All repairs must be cord is necessary, this has to be done entrusted to an authorized service by the manufacturer or their agent in center. Incorrectly performed repairs order to avoid a safety hazard. could lead to injury or death.
  • Page 18 User Manual Q-Tech Q-P019 - Electric Airless Spray Pump Problem: Motor cannot maintain pressure Check Solution Oversized tip Use correct tip for sprayer Tip worn to become oversize Relieve pressure and replace tip Problem: Low output Check Solution Worn tip...
  • Page 19 www.aristospray.com WIRING...
  • Page 20 User Manual Q-Tech Q-P019 - Electric Airless Spray Pump QP019 EXPLODED VIEW...
  • Page 21 www.aristospray.com...
  • Page 22 User Manual Q-Tech Q-P019 - Electric Airless Spray Pump QP019 PARTS LIST Q-TECH PART NO. ITEM DESCRIPTION QP019-01 SOCKET CAP SCREW M5 x 50 QP019-02 SOCKET CAP SCREW M5 x 25 QP019-03 SOCKET CAP SCREW M5 x 6 QP019-04 CRANK HOUSING...
  • Page 23 QP019 PARTS LIST Q-TECH PART NO. ITEM DESCRIPTION QP019-42 SOCKET CAP SCREW M5 x 25 QP019-43 GUIDE CYLINDER Ø26 x Ø32 x 30 QP019-44 RETAINING RING IR-32 QP019-45 DRIVE PISTON QP019-46 WRIST PIN-ROD Ø10 x 23.5 QP019-47 PACKING NUT...
  • Page 24 Aristospray UK London Dublin Granville House 2b Stephenstown Wallingford Road Industrial Park Uxbridge Balbriggan UB8 2RW Co. Dublin T 01895 276751 T 00353 1690 3162 E sales@aristospray.com F 00353 1690 3480 E sales@aristospray.com www.aristospray.com...

Table of Contents