Criteria D: Loss of function or degradation of performance which is not recoverable, owning to damage to
hardware or software, or loss of data.
8.4.2
Mains Drop-out Immunity
Standard Reference: IEC 61000-4-11:2004
- Variation 0% (= 100% dip) at T-event = 50msec. Performance criteria B
- Variation 40% (= 60% dip) at T-event = 100msec. Performance criteria B
- Variation 0% (= 100% dip) at T-event = 1 sec. Performance criteria C
Additional for USA:
- Variation 0% (= 100% dip) at T-event = 100msec in standby mode. Performance criteria B
Performance criteria:
Criteria A: Normal performance;
Criteria B: Temporary loss of function or degradation of performance which ceases after the disturbance
ceases, and from which the equipment under test recovers its normal performance, without operator
intervention;
Criteria C: Temporary loss of function or degradation of performance, the correction of which requires operator
intervention;
Criteria D: Loss of function or degradation of performance which is not recoverable, owning to damage to
hardware or software, or loss of data.
8.4.3
Surge Immunity (Lightning Test)
Standard Reference: IEC61000-4-5:2005
The product shall withstand mains interferences of
For Europe:
Differential Mode: ±2kV / 2ohm, Performance criteria C
Parameters: Bi-wave, Open circuit voltage: 1.2/50µs, Short circuit current: 8/20µs.
Range: ± 0.5kV to ± 2kV, in steps of 0.5kV. 10 shots per combination. One shot per minute.
Serial impedance: 2ohm. Polarity: Positive and Negative. Phase angle: 90
Common Mode: ±6kV / 2ohm, Performance criteria C
Parameters: Bi-wave, Open circuit voltage: 1.2/50µs, Short circuit current: 8/20µs.
Range: ±3kV to ±6kV, in step of 1kV. 10 shots per combination. One shot per minute.
Serial impedance: 2ohm. Polarity: Positive and Negative. Phase angle: 90
For NAFTA:
Differential Mode: ±6kV / 12ohm, Performance criteria C
Parameters: Bi-wave, Open circuit voltage: 1.2/50µs, Short circuit current: 8/20µs.
Range: ± 1kV to ± 6kV in steps of 1kV. 10 shots per combination. One shot per minute.
Serial impedance: 12ohm. Polarity: Positive and Negative. Phase angle: 90
Common Mode: ±6kV / 12ohm, Performance criteria C
Parameters: Ring-wave, 100kHz,
Range: ±3kV to ±6kV, in step of 1.5kV. 10 shots per combination. One shot per minute.
Serial impedance: 12ohm. Polarity: Positive and Negative. Phase angle: 90
For others:
Follow Europe requirements.
With the following requirement,
Apparatus should fulfill the leakage current requirements of less than 3mA after the Surge Immunity
test.
Defects or permanent deviations are not allowed.
Performance criteria:
Criteria A: Normal performance;
Criteria B: Temporary loss of function or temporary degradation of performance not requiring an operator;
Criteria C: Temporary loss of function or temporary degradation of performance requiring an operator;
Criteria D: Loss of function with permanent damage to equipment (which means failing the test).