Installation Requirements - Nordyne G6RC 90+ Installation Instructions Manual

G6rc series 90+ upflow condensing furnace g6rd series 93+ upflow condensing furnace g6rl series 90+ downflow condensing furnace
Table of Contents

Advertisement

INSTALLATION REQUIREMENTS

Requirements and Codes
This furnace must be installed in accordance
with these instructions, all applicable local build-
ing codes, and the current revision of the Na-
tional Fuel Gas Code (ANSI-Z223.1, NFPA-54).
The current revision of the National Fuel Gas
Code is available from:
American National Standards Institute, Inc.
1430 Broadway
New York, New York 10018
Canada installations shall comply with CAN/
CGA-B149 installation codes, local plumbing or
waste water codes and other applicable codes.
Additional helpful publications are:
• NFPA-90A - Installation of Air Conditioning
and Ventilating Systems.
Furnace
Model
Btuh
Number
G6R(C,D)040C
40,000
G6R(C,D)060C
60,000
G6R(C,D)080C
80,000
G6R(C,D)100C
100,000
G6R(C,D)120C
120,000
G6RL040C
40,000
G6RL060C
60,000
G6RL080C
80,000
G6RL100C
100,000
Table 3. Furnace Dimensions and Shipping Weights
CLEARANCES TO COMBUSTIBLE MATERIALS
This furnace is Designed Certified by AGA/CGA Laboratories for the minimum clearances to
combustible material listed in Table 4. See the furnace name plate, located inside the furnace
cabinet, for specific model number and clearance information.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIAL
Furnace
Cabinet
Input
Width
(Btuh)
(Inches)
40,000
14 1/4
60,000
14 1/4
80,000
14 1/4
100,000
19 3/4
120,000
22 1/2
* 24 inches is the minimum clearance for servicing.
36 inches is the recommended clearance for service.
Table 4. Minimum Clearances to Combustible Materials
8
• NFPA-90B - Warm Air Heating and Air
Conditioning Systems.
These publications are available from:
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, Massachusetts 02269
This furnace is not approved for in-
stallation in mobile homes. Installa-
tion in a mobile home could cause
fire, property damage, and/or personal
injury.
Dimensions (inches)
A
B
14 1/4
12 3/4
14 1/4
12 3/4
19 3/4
18 1/4
19 3/4
18 1/4
22 1/2
21
14 1/4
12 3/4
14 1/4
12 3/4
19 3/4
18 1/4
19 3/4
18 1/4
Minimum Clearances (Inches)
Side
Vent
0
0
0
0
0
0
0
0
0
0
WARNING:
!
C
D
5 1/8
11 3/4
5 1/8
11 3/4
7 7/8
17 1/4
7 7/8
17 1/4
9 1/4
20
4 5/8
12 3/4
4 5/8
12 3/4
10
18 1/4
10
18 1/4
Back
Top
0
1
0
1
0
1
0
1
0
1
Shipping
Weight
(lbs)
133
140
172
180
204
135
135
174
185
Front
1*
1*
1*
1*
1*

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents