FGT COLOR frame grabber board and FGT software in your computer. (see "FGT Frame Grabber User Guide") run the system V 1.1 July 2000 Phone +33 (0) 1 69 33 00 00 - Fax +33 (0) 1 69 33 03 21 CAMELIACOL 2.5M 2.5 MEGAPIXEL COLOR DIGITAL CAMERA www.atmel-grenoble.com User guide 1/12...
CAMELIACOL 2.5M user guide 1. IMAGING SYSTEM DESCRIPTION 2. CAMELIA COLOR 2.5M CAMERA Timing Anti-blooming by clocking Electrical interfaces : 2.4.1 Power supply : 2.4.2 digital I/O 2.4.3 RS232 interface Electro-optical performance Geometrical specifications Environmental requirements 3. CONNECTORS AND CABLES ‘’Data and sync’’...
"SHUTTER" signal delivered by the camera. If required, the system can send an external trigger or external ITC (integration time control signal) to the camera. CAMELIA POWER RS232 DATA & SYNC ELECTRO-OPTICAL INTERFACE TRIG_ITC CAMELIACOL 2.5M user guide 3/12...
CAMELIACOL 2.5M user guide 2. CAMELIA COLOR 2.5M CAMERA 2.1 CCD image format : 35.9mm(V) x 26.5mm(H) 1840(V) x 1360(H) active pixels readout register along the small side of the image area. (vertical image) pixel geometries : 19.5µm(V) x 19.5µm(H).
Page 5
Timing diagram (for operation with ‘’integration time control’’) : FRAME INTEGRATION SHUTTER shutter delay FRAME READOUT 1360 pixels video lines shutter delay FRAME READOUT 1360 pixels video lines shutter delay FRAME READOUT 1360 pixels video lines CAMELIACOL 2.5M user guide WAITING WAITING 5/12...
CAMELIACOL 2.5M user guide 2.3 A BLOOMING BY CLOCKING Anti-blooming can be activated or inhibited (see 2.5.3) : anti-blooming OFF : this position is recommended if anti-blooming is not required for the application. anti-blooming ON : anti-blooming operation reduces the pixel saturation charge. As a consequence, camera gain must be set to 1.30x (see 2.5.3) minimum in order to reach the camera saturation level (4095 adu)
‘’CDS gain’’ : a commutation 1x or 4x is available at the input of the video signal processing. Use of the 4x position is recommended for low level applications (noise is lower) or ‘’camera gain’’ : a range of 1x to 2x is available in 16 steps. CAMELIACOL 2.5M user guide Comment image size : 1360(H) x 1840(V)
CAMELIACOL 2.5M user guide 2.5 E LECTRO OPTICAL PERFORMANCE Conditions : frame integration time : 40ms camera operating free air temperature : 25°C Performance : Parameter Full scale value see note 2 Temporal noise see note 3 Dark signal non uniformity...
Spectral responsivity CAMELIA COLOR 2.5M 10000 8000 6000 4000 2000 Note : µJ/cm measured on the CCD chip. Including BG38 2mm. Wavelength (nm) CAMELIACOL 2.5M user guide Green Blue 9/12...
CAMELIACOL 2.5M user guide 2.6 G EOMETRICAL SPECIFICATIONS 4 X M3 2 X ø 2.0 mm ø 66.0 mm 10/12 FRONT PANEL 74.0 mm 64.0 mm REAR PANEL DATA & SYNC TH 31CA179M Made in France POWER RS 232 110.5 mm 25.6 mm...
"Data + Sync" cable is provided with FGT Frame grabber, including a part to be connected to the electro-optical interface, and the second one to the "FGT" frame grabber : see "FGT Frame Grabber user manual". Pin n° COLOUR_O1+ (1) COLOUR_O1-(1) COLOUR_I2+(1) COLOUR_I2-(1) CAMELIACOL 2.5M user guide Signal LEN+ LEN- GROUND GROUND PDATA1+ PDATA1-...
No license is granted by implication or otherwise under any patent rights of Atmel-Grenoble. Specifications mentioned in this publication are subject to change without notice.
Need help?