Technical Data

EEDEN14-131A
AZQS-BV1

Advertisement

Table of Contents
loading

Summary of Contents for Daikin ACQ71C/AZQS71BV1

  • Page 1: Technical Data

    Air Conditioning Technical Data EEDEN14-131A AZQS-BV1...
  • Page 3: Table Of Contents

    • Outdoor Unit • AZQS-BV1 TABLE OF CONTENTS AZQS-BV1 Features ............. 2 Specifications .
  • Page 4: Features

    S - B O u t A Z Q • Daikin outdoor units are neat, sturdy and can easily be mounted on a • Outdoor units for pair application roof or terrace or simply placed against an outside wall •...
  • Page 5: Specifications

    • Outdoor Unit • AZQS-BV1 Specifications 2-1 Capacity and Power input ACQ71C/AZQS71BV1 ACQ100C/AZQS100BV1 ACQ125C/AZQS125BV1 Cooling capacity Nom. 12.1 Heating capacity Nom. 7.50 10.80 13.5 Power input Cooling Nom. 2.05 2.96 4.02 Heating Nom. 2.08 2.99 3.96 Seasonal efficiency Cooling Energy label...
  • Page 6: Technical Specifications

    • Outdoor Unit • AZQS-BV1 Specifications 2-3 Capacity and Power input AHQ71C/AZQS71BV1 AHQ100C/AZQS100BV1 AHQ125C/AZQS125BV1 AHQ140C/AZQS140BV1 Seasonal efficiency Cooling Energy label (according to Pdesign 6.80 9.50 EN14825) SEER 4.65 4.60 Annual energy consumption Heating (Average Energy label climate) Pdesign 6.33 7.60 SCOP 3.80 Annual energy...
  • Page 7 • Outdoor Unit • AZQS-BV1 Specifications 2-4 Technical Specifications AZQS71BV1 AZQS100BV1 AZQS125BV1 AZQS140BV1 Fan motor Quantity Model KFD-325-70-8A Brushless DC motor Output Drive Direct drive Speed Steps Cooling Nom. Super Heating Nom. Super Sound power level Cooling Heating Sound pressure level Cooling Nom.
  • Page 8: Electrical Specifications

    • Outdoor Unit • AZQS-BV1 Specifications 2-5 Electrical Specifications AZQS71BV1 AZQS100BV1 AZQS125BV1 AZQS140BV1 Power supply Name Phase Frequency Voltage 220-240 Voltage range Min. Max. Current Nominal running Cooling 16.20 current (RLA) Zmax List Complies to EN6100-3- Complies to EN61000-3-12 Recommended fuses Current - 50Hz Maximum fuse amps (MFA) Current - 60Hz...
  • Page 9: Electrical Data

    • Outdoor Unit • AZQS-BV1 Electrical data 3 - 1 Electrical Data AZQS-BV1 AZQS-BY1 3D080873D • Split - Sky Air • AZQS-BV1...
  • Page 10: Options

    • Outdoor Unit • AZQS-BV1 Options 4 - 1 Options • Split - Sky Air • AZQS-BV1...
  • Page 11: Combination Table

    • Outdoor Unit • AZQS-BV1 Combination table 5 - 1 Combination Table AZQS-BV1 AZQS-BY1 4D080870D • Split - Sky Air • AZQS-BV1...
  • Page 12: Capacity Tables

    • Outdoor Unit • AZQS-BV1 Capacity tables 6 - 1 Cooling Capacity Tables • Split - Sky Air • AZQS-BV1...
  • Page 13: Heating Capacity Tables

    • Outdoor Unit • AZQS-BV1 Capacity tables 6 - 2 Heating Capacity Tables • Split - Sky Air • AZQS-BV1...
  • Page 14: Cooling/Heating Capacity Tables

    • Outdoor Unit • AZQS-BV1 Capacity tables 6 - 3 Cooling/Heating Capacity Tables &Z &  t   t     d D ^, ^ W/  W/ W  t   ^, ^, &Z &    t >...
  • Page 15 • Outdoor Unit • AZQS-BV1 Capacity tables 6 - 3 Cooling/Heating Capacity Tables &Z &  t   t     d D ^, ^ W/  W/ W  t   ^, ^, &Z &    t >...
  • Page 16 • Outdoor Unit • AZQS-BV1 Capacity tables 6 - 3 Cooling/Heating Capacity Tables &Z &  t   t     d D ^, ^ W/  W/ W    t ^, ^, &Z &    t >...
  • Page 17: Capacity Correction Factor

    • Outdoor Unit • AZQS-BV1 Capacity tables 6 - 4 Capacity Correction Factor • Split - Sky Air • AZQS-BV1...
  • Page 18: Dimensional Drawings

    • Outdoor Unit • AZQS-BV1 Dimensional drawings 7 - 1 Dimensional Drawings • Split - Sky Air • AZQS-BV1...
  • Page 19: 7 Dimensional Drawings

    • Outdoor Unit • AZQS-BV1 Dimensional drawings 7 - 1 Dimensional Drawings • Split - Sky Air • AZQS-BV1...
  • Page 20: Centre Of Gravity

    • Outdoor Unit • AZQS-BV1 Centre of gravity 8 - 1 Centre of Gravity • Split - Sky Air • AZQS-BV1...
  • Page 21: 8 Centre Of Gravity

    • Outdoor Unit • AZQS-BV1 Centre of gravity 8 - 1 Centre of Gravity • Split - Sky Air • AZQS-BV1...
  • Page 22: Piping Diagrams

    • Outdoor Unit • AZQS-BV1 Piping diagrams 9 - 1 Piping Diagrams • Split - Sky Air • AZQS-BV1...
  • Page 23: Wiring Diagrams

    • Outdoor Unit • AZQS-BV1 Wiring diagrams 10 - 1 Wiring Diagrams - Single Phase • Split - Sky Air • AZQS-BV1...
  • Page 24 • Outdoor Unit • AZQS-BV1 Wiring diagrams 10 - 1 Wiring Diagrams - Single Phase • Split - Sky Air • AZQS-BV1...
  • Page 25: Sound Data

    • Outdoor Unit • AZQS-BV1 Sound data 11 - 1 Sound Power Spectrum • Split - Sky Air • AZQS-BV1...
  • Page 26: Sound Pressure Spectrum - Cooling

    • Outdoor Unit • AZQS-BV1 Sound data 11 - 2 Sound Pressure Spectrum - Cooling • Split - Sky Air • AZQS-BV1...
  • Page 27: Sound Pressure Spectrum - Heating

    • Outdoor Unit • AZQS-BV1 Sound data 11 - 3 Sound Pressure Spectrum - Heating • Split - Sky Air • AZQS-BV1...
  • Page 28: Sound Pressure Spectrum Quiet Mode

    • Outdoor Unit • AZQS-BV1 Sound data 11 - 4 Sound Pressure Spectrum Quiet Mode • Split - Sky Air • AZQS-BV1...
  • Page 29: Installation

    • Outdoor Unit • AZQS-BV1 Installation 12 - 1 Installation Method • Split - Sky Air • AZQS-BV1...
  • Page 30 • Outdoor Unit • AZQS-BV1 Installation 12 - 1 Installation Method • Split - Sky Air • AZQS-BV1...
  • Page 31: Operation Range

    • Outdoor Unit • AZQS-BV1 Operation range 13 - 1 Operation Range ZQS- (Cooling) (Heating) Indoor temp. (°CWB) Indoor temp. (°CDB) Notes: Depending on operation and installation conditions, the indoor unit can change over to freeze-up operation (indoor de-icing). To reduce the freeze-up operation (indoor de-icing) frequency, it is recommended to install the outdoor unit in a location not exposed to wind.
  • Page 33 All content is copy- righted by Daikin Europe N.V. Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende...