13.14.1.9 Rhythmic Temperature Wave Operation
To further maximize the energy saving during ECONAVI or AUTO COMFORT operates at low activity level.
Start condition
The unit is operates in Cool or Dry mode under ECONAVI or AUTO COMFORT operation, and
o
Human activity sensor detects low activity level, and
o
Neuro stable zone continuously for 60 minutes.
o
Stop condition
Unit is off, or
o
ECONAVI or AUTO COMFORT is off, or
o
Human activity sensor detects high activity level or absent, or
o
Control contents
When all start conditions complied, set temperature will shift accordingly as following: