13.1.5
Automatic Operation
•
This mode can be set using remote control and the operation is decided by remote control setting temperature,
remote control operation mode and indoor intake air temperature.
•
During operation mode judgment, indoor fan motor (with speed of Lo-) is running for 30 seconds to detect the
indoor intake air temperature.
•
Every 10 minutes, the indoor temperature is judged.
•
For the 1st judgment
If indoor intake temperature - remote control setting temperature ≥ 2°C, COOL mode is decided.
o
If -2°C ≤ indoor intake temperature - remote control setting temperature < 2°C, DRY mode is decided.
o
If indoor intake temperature - remote control setting temperature < -2°C, HEAT mode is decided.
o
•
For the 2nd judgment onwards
If indoor intake temperature - remote control setting temperature ≥ 3°C, if previous operate in DRY mode,
o
then continue in DRY mode. otherwise COOL mode is decided.
If -2°C ≤ indoor intake temperature - remote control setting temperature < 3°C, maintain with previous mode.
o
If indoor intake temperature - remote control setting temperature < -2°C, HEAT mode is decided.
o
13.2 Indoor Fan Motor Operation
13.2.1
Basic Rotation Speed (rpm)
A. Basic Rotation Speed (rpm)
i. Manual Fan Speed
[Cooling, Dry]
•
Fan motor's number of rotation is determined according to remote control setting.
[Heating]
•
Fan motor's number of rotation is determined according to remote control setting.
ii Auto Fan Speed
[Cooling, Dry]
•
According to room temperature and setting temperature, indoor fan speed is determined automatically.
•
When set temperature is not achieved, the indoor fan will operate according to pattern below.
•
When set temperature achieved, the indoor fan speed will be fixed. When thermostat off, the fan stop periodically.
Remote control
○
Tab
Hi
Remote control
○
Tab
SHi
○
○
○
Me+
Me
Me-
○
○
○
Me+
Me
Me-