LG GR-B197DVCA Service Manual page 88

Hide thumbs Also See for GR-B197DVCA:
Table of Contents

Advertisement

2-9. Micom
Problems
Symptom
Bad PCB
All display
Bad connection
electric power.
LEDS are off.
between Main PCB
and display circuit.
Defective PCB trans.
DefectivePCB electric
circuit parts.
Abnormal
Bad connection
display LED
between Main PCB
operation
and display circuit.
Defective LED
module.
Causes
Bad connector
Visual check on connector
connection from main
connection.
PCB to display PCB.
PCB Trans winding is
Check resistance of PCB Trans Replace PCB Trans
cut.
input and output terminals with
PCB Trans temperature a tester. (If resistance is infinity,
fuse is burnt out.
trans winding is cut).
Defective regulator IC
Check voltage at input/output
(7812, 7805).
terminals.
PCB electric terminal
Check fuse in PCB electric
fuse is burnt out.
terminal with a tester.
STR Parts are
Check if STR No. 2 and 3 pins
damaged.
are cut when power is off.
Lead Wire connecting
Check Lead Wire terminals
main PCB and display
connecting Main PCB and
PCB is cut or connector display PCB with a tester.
terminal connection is
bad.
Defective LED.
Check if all LEDs are on when
Main PCB Test switch is
pressed (or when both freezer
key and power freezer key are
pressed at the same time for
more than one second.)
Checks
Measures
Reconnect
connector.
or PCB.
Replace regulator.
Replace PCB fuse.
Replace parts.
Reconnect Lead
Wire and directly
connect defective
contact terminal to
Lead Wire.
Replace display
PCB.
Remarks
Applicable to
model without
dispenser.
Refer to electric
circuit in circuit
explanation.
Applicable to
model with
dispenser.
Refer to display
circuit in circuit
explanation.

Hide quick links: