Electrical Service Guide For 230 Vac Model; Installing Wire Spool And Adjusting Hub Tension - MAC TOOLS MW135 Owner's Manual

Table of Contents

Advertisement

3-7. Electrical Service Guide For 230 VAC Model

Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1996 National Electrical Code (NEC)

3-8. Installing Wire Spool And Adjusting Hub Tension

Standard Wire Spool (8 in)
OM-210 089 Page 16
Install spool so welding wire feeds from bottom.
Adjusting Hub Tension
Turn wingnut. When a slight force is
needed to turn spool, tension is set.
1 Lb Wire Spool (4 in)
Tools Needed:
230
19.5
30
14
66 (20)
14
S-0092-J
15/16 in
S-0499