Installation
Figure 5
5A. Power Supply: This pump requires a 115 V.,
60 Hz., 15 amp individual branch circuit.
The circuit must be grounded and should be
dedicated to the sump pump.
5B. The pump is supplied with a 3-wire cord set
with grounding-type plug. Plug the switch
directly into the outlet and plug the pump into
the opposite end of the switch's plug.
Electrical shock hazard. Always
ground the pump to a suitable electrical
ground, such as a grounded water pipe, a
properly grounded metallic raceway, or a
ground wire system. Do not cut off the round
ground pin.
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
Figure 6
6A. After you have installed the piping, check
valve, and float switch, the pump is ready
for operation.
6B. Check the pump by filling the sump with water
and observing the pump's operation through
one complete cycle. For switch settings see
Electrical and Switch Specifications.
Risk of flooding. Failure to make
this operational check may lead to improper
operation, premature failure, and flooding.
4