cable.
2. Turn Booster Off.
3. Be sure cable TV provider is hooked up to exterior inlet.
Antenna:
1. Turn booster on.
2. Raise and adjust antenna. Jumper cable should be installed.
SOLAR PANEL (option)
Airstream uses the Carmanah Technologies Corp. Solar Panel/Charger
Controller/Display System. A manual on the use of the system is included with
the Airstream Owner's Blue Delivery Case.
Carmanah Technologies Corp.
Building 4, 203 Harbour Road
Victoria, BC V9A 3S2
Tel: 800-667-6527
Fax: 866-607-6527
www.solarforrv.com
The diagram on the next page shows the wire location for the factory installed
option.
1. YELLOW (like the sun) positive and GREEN (like the earth) negative leads runs
from battery breaker buss bar area to a harness inside the exterior refrigerator
access door on units manufactured early in the model year. The battery buss
bar is located on the front end shell inside skin next to the battery compartment.
Front bed models have the bar located under the front bed. Battery cables will
run to this bar. Roof mounted panels require dropping the panel wires down
through the refrigerator vent to the inside of the exterior refrigerator access
door. Portable solar panels can be set outside close to the access door. The
wires from the solar panel are connected to the positive and negative wires
(yellow and green) of the pre-wire system.
On later models the yellow and green leads run from the battery buss bar to
under the center roof sheet just behind the front roof vent on 19', 20', 23' Front
Bed, and 25' Front Bed models and just in front of the rear roof vent on 23',
27' Front Bed, 28', and 30' models. No wires are ran to exterior refrigerator
compartment. Roof mounted panels require cutting a hole in center sheet and
fishing the wires out to be connected to the panel.
2. A Cat 5 patch cord for the solar panel display runs from the battery buss bar
to an area just below the CatCon seven display. The solar panel display panel
can be mounted just below the CatCon monitor panel by routing the proper
G - 11