Bosch HBL53 Installation Manual page 18

500/800 series
Hide thumbs Also See for HBL53:
Table of Contents

Advertisement

Available languages

Available languages

Combination Oven and Steam Oven 30"
Flush installation requires two side cleats to be attached
inside the cabinet frame, recessed from the front.
It is good practice, when oven is installed at the end of a
cabinet run, adjacent to a perpendicular wall or cabinet
door, to allow at least 1/4" space between the side of the
oven and the wall/door.
For oven support, install 2x4's extending front to back flush
with the bottom and the side of the opening. The supporting
base must be well secured to the floor/cabinet and level.
Note:
The conduit box must be located above the unit to facilitate
connecting and servicing.
The cabinet cavity must be plumb and the base must be flat
and level and capable of supporting a weight of at least 429
lbs (195 kg).
English 15
Single Oven, Undercounter 30"
Flush installation requires two side cleats to be attached
inside the cabinet frame, recessed from the front.
It is good practice, when oven is installed at the end of a
cabinet run, adjacent to a perpendicular wall or cabinet
door, to allow at least 1/4" space between the side of the
oven and the wall/door.
For oven support, install 2x4's extending front to back flush
with the bottom and the side of the opening. The supporting
base must be well secured to the floor/cabinet and level.
The cabinet cavity must be plumb and the base must be flat
and level and capable of supporting a weight of at least 212
lbs (96 kg).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents