  • Page 1 INTEGRA INTEGRA COMPACT User manual...
  • Page 2 INTEGRA Compact 250 / 500 INTEGRA Compact 250 / 500 Control panel (back view) Control panel (back view) READY right left TEST SLAVE PROP 1/16 FULL 230V / 50-60Hz MADE IN GERMANY bottom...
  • Page 3 HENSEL Studiotechnik HENSEL Studiotechnik GmbH & Co.KG GmbH & Co.KG Robert-Bunsen-Str. 3 Robert-Bunsen-Str. 3 D-97076 Würzburg-Lengfeld D-97076 Würzburg-Lengfeld GERMANY GERMANY Phone: Phone: +49 (0) 931/27881-0 +49 (0) 931/27881-0 Fax: Fax: +49 (0) 931/27881-50 +49 (0) 931/27881-50 E-Mail: E-Mail: info@hensel.de info@hensel.de...
  • Page 5: Introduction

    INTEGRA Introduction Dear Photographer, in buying a HENSEL flash system, you have purchased powerful equipment of high quality. So that you are able to successfully and productively work with this system for many years, we are giving you some advice on the use of this high tech product.
  • Page 6: Table Of Contents

    Replacement of fuses ........14 Replacement of modeling lamp ..... 14 Replacement of flashtube ......15 Regular inspection ......... 16 Return to customer service ......16 Disposal ............... 16 Accessories............16 Customer service ..........16 Certificate of Conformity ........17 HENSEL Studiotechnik...
  • Page 7: General Safety Regulations

    For this reason it is a must to protect pilot and flash light with the supplied correctly installed HENSEL protection glass dome. The glass dome is available in different versions. The use of the glass dome changes the colour temperature.
  • Page 8: Standard Delivery

    INTEGRA 250/500 Bi-Voltage is equipped with a sliding switch which allows either 230V or 115V operation. The units are supplied with: • Flashtube, single coated, user replaceable • Protection glass dome, clear, uncoated • Tilting Head with integrated umbrella holder • Cableset: Power and Sync. cord HENSEL Studiotechnik...
  • Page 9: Technical Data

    2 AF 4 AF 2 AF 4 AF Mains connection: manual switchable: 230 V∼ /115 V∼ Weight (kg): Measurements (LxWxH) in cm: 31 x 12,6 x 19,7 31 x 12,6 x 19,7 Code No.: 8802 8812 Technical changes reserved. HENSEL Studiotechnik...
  • Page 10: Overview Of Controls

    Turn off the appliance for each change of reflectors or to move the unit to another location. Caution: Reflectors, speedrings and other accessories heat up during longer operation. To avoid injuries, handle with isolating cloth or wait, till parts cooled down. HENSEL Studiotechnik...
  • Page 11: Acclimatizing

    This is done by tightening the safety screw (not included in the standard delivery) into the thread of the HENSEL Tilting Head. Due to the existing safety regulations, it is, however, necessary to use a safety rope (code no.
  • Page 12: Positioning

    Above the tillting head an umbrella holder e is integrated. Accessories All HENSEL reflectors and HENSEL softboxes of series EHT (adapter Ø: 10 cm), accessories included, may be attached to the INTEGRA compact flash; also umbrellas and Softstar.
  • Page 13: Mains Connection

    115 V mains voltage with a fuse 4 A fast (4 AF). 4 AF Before starting up the Bi-Voltage version check the provided fuse! Make sure, that the position of the sliding switch 11 corresponds to the mains voltage. More information on page 14, Replacement of fuses. HENSEL Studiotechnik...
  • Page 14: Overheating

    IR. Synchronization by infrared triggering system For remote-controlled triggering, an infrared triggering system is available as accessory: receiver and transmitter IR Transmitter and Receiver „Speed“ „Speed“ Code 392 (Set) or 393 (Transmitter) + 394 (Receiver) HENSEL Studiotechnik...
  • Page 15: Flash Power Control

    This shows correct charge as well as readiness to flash. The flash check mode guarantees that the flash heads have triggered when more than one flash unit is used. HENSEL Studiotechnik...
  • Page 16: Maintenance

    (see paragraph replacement of fuses above). For all types of INTEGRA compact flash units only use max. 300 W / G 6,35 Halogen as modeling light. For order please look up the Code No. in the following table. HENSEL Studiotechnik...
  • Page 17: Replacement Of Flashtube

    Then pull out flashtube and replace it with a new one. Finally connect the ignition cable. You must make sure that the appropriate flashtube is used. Please order from HENSEL: Flashtube, user replaceable, for INTEGRA Compact, single coated, Code No. 9450401.
  • Page 18: Regular Inspection

    Reflectors and Softboxes with small accessory adapter diameter (10 cm) for series EHT/EXPERT/CONTRA Umbrellas Customer Service Works customer service with 24 hours express service: HENSEL Studiotechnik GmbH & Co. KG GERMANY - service department - Robert-Bunsen-Str. 3 D-97076 Würzburg Phone: +49(0)931/27881-0 Fax: +49(0)931/27881-50 info@hensel.de...
  • Page 19: Certificate Of Conformity

    INTEGRA Certificate of Conformity for Electromagnetic Compatibility and Safety Manufacturer and HENSEL Studiotechnik GmbH & Co.KG Owner of Certification: Robert-Bunsen-Str. 3 97076 Würzburg Germany Test Report: of October 27, 1999 Product: Compact Flash Units INTEGRA 250 / INTEGRA 500...