*DY120R9V5W - FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOW
SETTING
LOW
MEDIUM LOW
HEATING
1ST
STAGE
NORMAL **
HIGH
LOW
MEDIUM LOW
HEATING
2ND
STAGE
NORMAL **
HIGH
NOTES:
* First letter may be "A" or "T"
** Factory setting
*DY120R9V5W - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
AIRFLOW
UNIT SIZE
SETTING
(TONS)
LOW
(350 CFM/TON)
NORMAL
3.5
(400 CFM/TON)
HIGH
(450 CFM/TON)
LOW
(350 CFM/TON)
NORMAL
4.0
(400 CFM/TON)
HIGH
(450 CFM/TON)
LOW
(350 CFM/TON)
NORMAL
5
(400 CFM/TON)
HIGH
(450 CFM/TON)
NOTES: * - First letter may be "A" or "T"
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
Page B-651-438
DIP SWITCH SETTING
SW 8
SW 7
CFM
ON
ON
TEMP. RISE
WATTS
CFM
OFF
ON
TEMP. RISE
WATTS
CFM
ON
OFF
TEMP. RISE
WATTS
CFM
OFF
OFF
TEMP. RISE
WATTS
CFM
ON
ON
TEMP. RISE
WATTS
CFM
OFF
ON
TEMP. RISE
WATTS
CFM
ON
OFF
TEMP. RISE
WATTS
CFM
OFF
OFF
TEMP. RISE
WATTS
DIP SWITCH SETTING
SW 1
SW 2
SW 3
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
1st STAGE CAPACITY =
2nd STAGE CAPACITY =
EXTERNAL STATIC PRESSURE
0.1
0.3
1025
1025
65
65
150
200
1200
1200
56
56
230
270
1350
1350
49
49
280
340
1550
1550
43
43
400
490
1550
1550
66
66
380
470
1850
1850
56
56
660
750
2050
2000
50
51
860
880
2105
2050
49
50
1000
940
SW 4
0.1
CFM
1225
ON
WATTS
240
CFM
1400
OFF
WATTS
310
CFM
1600
OFF
WATTS
450
CFM
1400
ON
WATTS
300
CFM
1600
OFF
WATTS
460
CFM
1800
OFF
WATTS
610
CFM
1750
ON
WATTS
580
CFM
2000
OFF
WATTS
830
CFM
2100
OFF
WATTS
970
Service Facts
74,000
112,000
0.5
0.7
1000
1000
67
67
240
290
1200
1200
56
56
330
390
1350
1350
49
49
490
470
1550
1550
43
43
560
620
1550
1550
66
66
540
610
1850
1700
56
60
780
720
1850
1700
56
60
810
750
1900
1775
54
58
880
820
EXTERNAL STATIC PRESSURE
0.3
0.5
0.7
1225
1225
1225
280
340
400
1400
1400
1400
390
470
520
1600
1600
1600
520
590
640
1400
1400
1400
380
450
520
1600
1600
1600
530
610
670
1800
1800
1650
700
760
690
1750
1750
1650
640
720
680
2000
1850
1700
860
800
740
2000
1900
1650
910
850
780
0.9
1000
67
340
1200
56
450
1350
49
530
1450
46
600
1450
71***
690
1500
69
640
1550
66
670
1625
63
750
0.9
1225
450
1400
570
1450
600
1400
570
1450
600
1500
630
1450
610
1550
660
1600
710
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents