Download  Print this page

American Standard AUY060R9V3W Service Facts Page 15

Hide thumbs

Advertisement

*DY080R9V3W FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOW
SETTING
LOW
MEDIUM LOW
HEATING
1ST
STAGE
NORMAL **
HIGH
LOW
MEDIUM LOW
HEATING
2ND
STAGE
NORMAL **
HIGH
NOTES: * - First letter may be "A" or "T"
** Factory setting
*** Above MAX Temperature change value
*DY080R9V3W - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
AIRFLOW
UNIT SIZE
SETTING
(TONS)
LOW
(350 CFM/TON)
NORMAL
2.0
(400 CFM/TON)
HIGH
(450 CFM/TON)
LOW
(350 CFM/TON)
NORMAL
2.5
(400 CFM/TON)
HIGH
(450 CFM/TON)
LOW
(350 CFM/TON)
NORMAL
3.0
(400 CFM/TON)
HIGH
(450 CFM/TON)
NOTES: * First letter may be "A" or "T"
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
Page B-651-438
DIP SWITCH SETTING
SW 7
SW 8
CFM
ON
ON
TEMP. RISE
WATTS
CFM
OFF
ON
TEMP. RISE
WATTS
CFM
ON
OFF
TEMP. RISE
WATTS
CFM
OFF
OFF
TEMP. RISE
WATTS
CFM
ON
ON
TEMP. RISE
WATTS
CFM
OFF
ON
TEMP. RISE
WATTS
CFM
ON
OFF
TEMP. RISE
WATTS
CFM
OFF
OFF
TEMP. RISE
WATTS
DIP SWITCH SETTING
SW 1
SW 2
SW 3
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
1st STAGE CAPACITY =
2nd STAGE CAPACITY =
EXTERNAL STATIC PRESSURE
0.1
0.3
800
800
56
56
130
170
900
900
49
49
162
210
1000
1000
44
44
205
265
1170
1170
38
38
305
350
1150
1150
60
60
285
345
1275
1275
54
54
380
445
1430
1340
48
51
515
490
1430
1340
48
51
515
490
SW 4
0.1
CFM
700
ON
WATTS
95
CFM
800
OFF
WATTS
130
CFM
900
OFF
WATTS
160
CFM
875
ON
WATTS
145
CFM
1000
OFF
WATTS
205
CFM
1150
OFF
WATTS
295
CFM
1050
ON
WATTS
235
CFM
1200
OFF
WATTS
335
CFM
1350
OFF
WATTS
455
Service Facts
49,000
73,000
0.5
0.7
800
790
56
56
210
245
900
900
49
49
260
295
1000
1000
44
44
310
345
1170
1020
38
44
400
360
1150
1020
60
67***
385
360
1200
1040
57
66***
425
380
1220
1090
56
63
455
410
1220
1090
56
63
455
410
EXTERNAL STATIC PRESSURE
0.3
0.5
0.7
700
700
680
105
115
200
800
800
790
160
205
245
900
900
900
215
255
300
875
875
875
185
240
280
1000
1000
1000
265
310
340
1150
1150
1020
340
385
350
1050
1050
1010
295
340
350
1200
1200
1040
385
410
365
1350
1210
1070
480
435
390
0.9
-
-
800
56
295
830
54
310
830
83***
305
900
76***
350
930
74***
380
930
74***
380
0.9
670
235
740
265
750
270
760
270
800
295
800
300
800
290
840
310
900
345