Procedure of CCD AORI checking
1. Click "AORI & CENTER" in adjustment menu.
2. Click MASTER BODY "AORI & CENTER" in AORI & CENTER Adjustment menu. (Fig. 1)
3. "Setting Data of master body has complete!" is displayed, then reading Master body data is complete.
4. Click "END" in AORI & CENTER Adjustment menu.
5. Click "ADJUSTMENT END" in adjustment menu.
6. Exchange Master camera for target camera.
Be careful to exchange camera to avoid any change to the setting.
7. Set camera to adjustment mode.
Refer to "Starting up the 2181 adjustment program (in the adjustment mode)" in P. **.
8. Click "AORI & CENTER" in adjustment menu.
9. Click CHECK "AORI" in AORI & CENTER Adjustment menu. (Fig. 1)
10. Check the numbers displayed in Aori Adjusment window, whther value of "C" and "dPI" is in the
range of standard value. (Fig. 2)
Standard value of C: From -10 to 10
Standard value of dPI: From -10 to 10