HEATING OPERATION
• Use the device for heating when the outdoor temperature is under 21°C.
When it is too warm (over 21°C), the heating function may not work in order to protect the device.
• In order to keep reliability of the device, please use this device above -15°C of the outdoor temperature.
1
Press the FUNCTION selector so that the display indicates
(HEAT).
Set the desired FAN SPEED with the
display indicates the setting).
2
Set the desired room temperature with the TEMPERATURE buttons
(the display indicates the setting).
3
The temperature setting and the actual room temperature may vary
somewhat depending on conditions.
Press the
START
a beep. Press the button again to stop operation.
STOP
■ As the settings are stored in memory in the remote controller, you only have
to press the
■ Defrosting
Defrosting will be performed about once an hour when frost forms on the heat exchange of the outdoor unit,
for 5~10 minutes each time.
During defrosting operation, the operation lamp blinks in cycle of 3 seconds on and 0.5 second off.
The maximum time for defrosting is 20 minutes.
However, if it is connected to multi type outdoor unit, the maximum time for defrosting is 15 minutes.
(If the piping length used is longer than usual, frost will likely to form.)
01_RAF_RAC-25,35,50NX2_EN A4
8
(FAN SPEED) button (the
(AUTO)
: The fan speed changes automatically according
to the temperature of the air which blows out.
(HI)
: Economical as the room will become warm
quickly.
But you may feel a chill at the beginning.
(MED)
: Quiet.
(LOW)
: More quiet.
(SILENT) : Silent.
(START/STOP) button. Heating operation starts with
(START/STOP) button next time.
– 8 –
5/17/10, 9:37 AM
DEHUMIDIFYING OPERATION
Use the device for dehumidifying when the room temperature is over 16°C.
When it is under 15°C, the dehumidifying function will not work.
Press the FUNCTION selector so that the display indicates
1
Press the
START
Press the
STOP
■ When you want to change the operation mode, please use the FUNCTION
selector.
■ Set the desired temperature is available.
■ You also can use the FUNCTION selector to select this operation.
■ Dehumidifying Function
• Dehumidifying takes place with a target temperature which is slightly lower than the room temperature
setting. (However, target temperature is 16°C for a temperature setting of 16°C.)
If the room temperature becomes lower than the target value, operation stops. If the room temperature
becomes higher than the target value, operation restarts.
• The preset room temperature may not be reached depending on the number of people present in the room
conditions.
01_RAF_RAC-25,35,50NX2_EN A4
9
(DEHUMIDIFY).
(FAN SPEED) button to select LOW and SILENT.
(START/STOP) button.
– 9 –
5/17/10, 9:37 AM

Advertisement