Patton SmartNode OpenScape Quick Start Manual

Smartnode openscape business appliance

Advertisement

Quick Links

SmartNode
OpenScape Business Appliance

Quick Start Guide

Important
industrial environment. It is not intended nor approved for use in an
Part Number: 07MSN-OSB-QS, Rev. A
Revised: December 1, 2015
—This is a Class A device and is intended for use in a light
industrial or residential environment.
REGULATORY MODEL NUMBER: 09417D4-001
Sales Office: +1 (301) 975-1000
Technical Support: +1 (301) 975-1007
E-mail: support@patton.com
WWW: www.patton.com

Advertisement

Table of Contents
loading

Summary of Contents for Patton SmartNode OpenScape

  • Page 1: Quick Start Guide

    It is not intended nor approved for use in an industrial or residential environment. REGULATORY MODEL NUMBER: 09417D4-001 Sales Office: +1 (301) 975-1000 Part Number: 07MSN-OSB-QS, Rev. A Technical Support: +1 (301) 975-1007 Revised: December 1, 2015 E-mail: support@patton.com WWW: www.patton.com...
  • Page 2 2002/96/EC on Waste of Electrical and Electronic Equip- ment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling. SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 3 Connect your computer to the Ethernet switch. An IP address will be assigned to your PC. refer to section 5.1 below Push the power Button at the back of the unit once (see figure SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 4: Basic Application

    SmartNode OpenScape Business Appliance basic connections 3.0 Basic Application Figure 2. SmartNode OpenScape Business Appliance Application Note Your favorite third-party switch is required for communication between the SmartNode and OpenScape Business UCC server. SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 5 Note For all SKUs please refer to the SmartNode OpenScape Business Appli- ance product page at www.patton.com. 4.0 SmartNode Ports 4.1 SN-OSB Models with SN4600 (SmartWare) Applies to models: • SN-OSB/2BIS2JS2JO8V/EUI • SN-OSB/4BIS4JS4JO12V/EUI • SN-OSB/4JS4JO/EUI • SN-OSB/8JS/EUI 4.2 SN-OSB Models with SN4980 (Trinity) Applies to model: •...
  • Page 6 4.3 SN-OSB Models with SN5570 (Trinity) Applies to models: • SN-OSB/1E15VHP/EUI • SN-OSB/1E30VHP/EUI 4.4 SN-OSB Models with SN5530 (Trinity) Applies to model: SN-OSB/4BIS8VHP/EUI • SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 7: Hardware Installation

    3 on page 7). There is a DHCP Server running on the SmartNode Gateway, while the OpenScape Business UCC server is running on a fixed IP address (192.168.1.9). Figure 3. Typical installation SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 8 Access the WBM, using your preferred web browser, by typing the following URL: https://192.168.1.9 Note If you are asked to accept the SSL certificate from OpenScape Business, click accept to proceed with the configuration. SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 9 WAN interface for Internet access and Internet tele- phony via an ITSP. The first LAN port is used as usual as a LAN interface for the internal phones and PCs. SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 10 Select the country code and language to be used for the event logs. 6.4 Selecting the Country Code and the Language for Trace Logs Prerequisites You are in the System Settings window (see figure Figure 5. Country Code and Language for Trace logs section SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 11 Linux or subsequently via YaST. Next steps Start the basic configuration. Additional OpenScape Business documentation figure 7 can be found in the Service Center, as shown in on page 12. SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 12 Gateway/E-SBC will have to be set up. The SmartNode Gateway/E-SBC can be configured by using the Command Line interface (CLI) or the Web interface. It’s recommended to generate a config file by using the WebWizard platform at Patton.com/wizard. SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 13: Contacting Patton For Assistance

    (RMA). 8.2 Contact information Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems.
  • Page 14: Warranty Coverage

    +1 301 869 9293 +41 31 985 2526 8.3 Warranty Service and Returned Merchandise Authorizations (RMAs) Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before shipment. All of our products are backed by a comprehensive warranty program.
  • Page 15 RMA#: xxxx 7622 Rickenbacker Dr. Gaithersburg, MD 20879-4773 USA Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return shipping costs. SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 16: Specifications

    12 DC V B.0 Cabling B.1 Serial Console (using RJ45 to DB-9 adapter, 19200 bps) Applies to models • SN-OSB/1E15VHP/EUI • SN-OSB/1E30VHP/EUI • SN-OSB/4BIS8VHP/EUI Figure 8. Connecting a serial terminal with RJ45 to DB-9 adapter SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 17 B.3 Serial Console (using male DB-9 to female DB-9 cable) Applies to model SN-OSB/4B/EUI. Figure 9. Connecting a serial terminal with male DB-9 to female DB-9 adapter Console connection settings: • 9600 bps • 8 bits, no parity SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 18 B.4 Ethernet Ethernet devices (10/100/1000 Base-T) are connected to the SmartNode over a cable with RJ-45 plugs. All Ethernet ports on the SmartNode OpenScape Business Appliance are Auto-MDX. Use any straight or crossover cable to a host, hubs, switches, PCs or other devices.
  • Page 19 WARNING 0 / 3 0 / 2 0 / 1 0 / 0 0 / 1 0 / 0 o le Cross-over cable Figure 12. Connecting an E1 PRI port to an NT1 SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 20 PRI port, regardless of when power is turned OFF To prevent damage to the system, make certain you con- nect the PRI cable to the PRI port only and not to any other RJ-45 socket. WARNING SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 21 RX Ring RX Ring RX Tip RX Tip RX Shield RX Shield TX Ring TX Ring TX Tip TX Tip TX Shield TX Shield *N/C = No connection* Figure 15. T1 PRI crossover cable SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 22 TE port of your phone, PBX, or residential S-BUS. SN4660 o le 0 / 2 0 / 0 RJ-45, male RJ-45, male Note: Other pins are not used. Figure 16. Connecting an ISDN device SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 23: Port Pin-Out

    Console connection settings: • 19200 bps • 8 bits, no parity • 1 stop bit • flow controls off Console Connection Settings for DB-9 Port Applies to model SN-OSB/4B/EUI Console connection settings: • 19200 bps SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 24 SN-OSB/4BIS4JS4JO12V/EUI • SN-OSB/4JS4JO/EUI • SN-OSB/8JS/EUI Console connection settings: • 9600 bps • 8 bits, no parity • 1 stop bit • flow controls off C.3 Ethernet Table 5. 10/100 Base-T RJ-45 socket Signal SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 25 Table 6. 1000Base-T RJ-45 Socket Signal TRD0+ TRD0- TRD1+ TRD1- TRD2+ TRD2- TRD3+ TRD3- C.4 ISDN PRI (E1/T1) Port Pin-outs Table 7. Port 0/0 Signal RX_TIP RX_RING TX_TIP TX_RING SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 26 When the unit is not powered, the fallback relay connects pins 3, 4, 5, and 6 of the BRI 0/0 and BRI 0/1 ports together. This enables you to place calls to the PSTN even if the unit is powered down. SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 27: Compliance Information

    Council Directive 2004/108/EC on the approximation of the laws of the member states relating to electromagnetic compatibility; Council Directive 2006/95/EC on the approximation of the laws of the member states relating to electrical equipment designed for use within certain voltage limits; Council SmartNode OpenScape Business Appliance Quick Start Guide...
  • Page 28 Oxford, OX1 1BE, UK Copyright statement Copyright © 2015, Patton Electronics Company. All rights reserved. The information in this document is subject to change without notice. Patton Electronics assumes no liability for errors that may appear in this document. Trademarks statement The term SmartNode is a trademark of Patton Electronics Company.

Table of Contents