Niles SI-275 Installation & Operation Manual page 12

Niles audio corporation systems integration amplifier installation & operation guide si-275
Hide thumbs Also See for SI-275:
Table of Contents

Advertisement

INSTALLATION
Page 11 Setting The Turn-On Mode
Page 11 Control Output
Page 12 Speaker Wire Connections
Setting the Turn-On Mode Switch
The SI-275 has three turn-on modes. Select which mode you desire by sliding the
mode switch. See Installation Considerations on page 6 for more information
about each of the turn-on modes.
Control Output
This terminal provides a 12V DC signal
suitable for triggering Niles automated
switchers, some motorized screens, some
electric curtain controls, etc. The trigger volt-
age is present only when the amplifier is
active or "on". When the amplifier turns "off",
the 12 Volt signal is off.
STEP
1. Check the requirements of the
device you want to control.
2. Connect the 3.5mm Jack to the
control output maintaining proper
polarity (tip = +)
11
Switch
Page 12 Line Level Audio Inputs
Page 13 Cascade Audio Outputs
Page 14 AC Power plug
Slide the switch with your fingernail or a
1/8" slotted screwdriver blade.
DESCRIPTION
The control output has a maximum
current capability of 12V DC 150 mA.
Niles makes an accessory cable
plug FG00724.
Using the
3.5mm jack.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Systems integration amplifier si-275

Table of Contents