Electrical
The electrical supply should be located in an adjacent
cabinet. If the supply cannot be located in an adjacent
cabinet, it must be located within the shaded area shown in
the illustration below. A separate circuit, servicing only this
appliance is required.
For the outdoor model, a ground fault
IMPORTANT NOTE:
circuit interrupter (GFCI) is required to reduce the risk of
electrical shock. A GFCI is not recommended for use with
other models and may cause interruption of operation.
Installation must comply with all applicable electrical codes.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Receptacle
OPENING
WIDTH
3
5
/
"
8
(137)
2"
AREA EXTENDS
(51)
FORWARD ON FLOOR
Electrical supply location.
115 VAC, 60 Hz
15 amp
3-prong grounding-type
Plumbing
The plumbing supply and drain should be located in an
adjacent cabinet. If they cannot be located in an adjacent
cabinet, they must be located within the shaded area shown
in the illustration below. The water supply line should be
connected to a hot or cold house supply with an easily
accessible shut-off valve between the supply and the unit.
Installation must comply with all applicable plumbing codes.
PLUMBING REQUIREMENTS
Water Supply
Pressure
OPENING
WIDTH
3
5
/
"
8
(137)
2"
AREA EXTENDS
(51)
FORWARD ON FLOOR
Water supply and drain location.
1
/
" OD copper, braided
4
stainless steel or PEX tubing
4.2–140 psi
(.3–9.7 bar)
|
askona.com/specs