7-1- 8 ERROR DIAGNOSTIC MODE
1. The error diagnostic mode allows the SVC when a fault that may affect the performance of the product occurs while
operating the product.
2. Even if the function control button is pushed when an error occurs, the function will not be performed. However, the
recognition tone (beep~) sounds.
3. When the error is cleared while the error code is displayed due to a fault, the appliance returns to the normal condition
(Reset).
4. The error code is displayed by the refrigerator temp indication LED on the display of the refrigerator while the remaining
LEDs are off.
u GR-M562Y*X/M602Y*X
GR-M562Y*Y/M602Y*Y
GR-B562Y*Y/B602Y*Y
GR-B562Y*Q/B602Y*Q
NO
Error
1
Faulty refrigerator
(R) sensor
Faulty defrosting
2
sensor
Faulty Room
temperature sensor
3
(in the main PCB)
4
Defrosting failure
Error Code
Display
Cut or short-circuited wire of
r
refrigerator sensor
Cut or short-circuited wire of
d
defrosting sensor
when super cool and
Cut or short-circuited wire of
refrigerator key pressed
intake air temperature sensor
together display will be all off
Cut or disconnected wire of
defrosting heater or temperature
H
fuse(indicated at least 4 hours
later after the error occurs)
Cause
Comp
15 min ON/
15 min OFF
Normal
Condition
Normal
Condition
Normal
Condition
- 22 -
State of Operation with Error
Cooling fan
Defrosting heater
Low
Normal
RPM
Condition
Low
No defrosting
RPM
Low
Normal
Condition
RPM
Low
Normal
Condition
RPM

Hide quick links: