7-1-4 DOOR OPEN ALARM

1. This function activate an alarm every time that door is opened for more than 1 minute
2. After 1 minute with door opened. The alarm sounds 3 times in intervals of 30 sec.
3. The alarm stops sounding when the door is closed or when the function of "door open alarm" is turned off.
This function could be deactivated or activated pushing DOOR ALARM button, the status is shown by a LED.
Freezer and
Refrigerator
Doors
Door
Alarm
LED
SOUND
7-1-5 DEFROST
The operation defrost start when the total time of compressor achieve 7h.
After to connect the refrigerator (or after the energy interrupted) the defrost will start after at 4h total of work compressor.
When the temperature of defrost sensor achieve 13 °C or more, the defrost was concluded. If after 2h is not achieve the
temperature of 13 °C, the display show a code of error on control display and will finish the defrost.
Starting the normal cycle of cooling (refer to diagnostic mode error, 8.1.4)
When the defrost sensor was damage (the sensor was damage or short circuit) the defrost operation will not make
(after detected the fail is necessary change the sensor).