Samsung ASA07C5(6)ME Service Manual page 18

Table of Contents

Advertisement

3-2-2(h) Refrigerant Adjustment
Class
Connection
Air-Purge
Pipe Length
Method
5m Max.
Refer to the
detailed Air-Purge
Procedure
5~10m
3-2-2(i) Flare nut fixing torque
Outter diameter
ø 6.35 (9000Btu, 12000Btu) (Liquid Side)
ø 9.52 (9000Btu) (Gas Side)
ø 12.7 (12000Btu) (Gas Side)
Samsung Electronics
For installation
Refrigerant
Adjustment
Unnecessary
Add 20g of refrigerant
R410A(Add as liquid
state) for every 1m.
Fixing Torque
160
300
500
Operating Instructions and Installation
For service
Air-Purge
Refrigerant
Method
Quantity
refer to
Purge air using a
specification sheet
vaccum pump
Add 20g of refrigerant
R410A(Add as liquid
state) for every 1m.
Torque (kg-cm)
Final Torque
200
350
550
3-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents