Service Mode; Dvd) Self-Diagnosis And Special Mode Setting - Panasonic DMR-EZ47VP Service Manual

Table of Contents

Advertisement

DMR-EZ47VP / DMR-EZ475VP

7 Service Mode

7.1.

(DVD) Self-Diagnosis and Special Mode Setting

7.1.1.
(DVD) Self-Diagnosis Functions
Self-Diagnosis Function provides information for errors to service personnel by "Self-Diagnosis Display" when any error has
occurred.
U**, H** and F** are stored in memory and held.
You can check latest error code by transmitting [0] [1] of Remote Controller in Service Mode.
Automatic Display on FL will be cancelled when the power is turned off or AC input is turned off during self-diagnosis display is ON.
Error Code
Diagnosis contents
U30
Remote control code error
U59
Abnormal inner temperature
detected
U61
The unit is carrying out its
recovery process.
U72
HDMI connection error
(communication error)
U73
HDMI connection error
(authentication error)
U76
Injustice disc error
U88
The unit is carrying out its
recovery process.
U99
Hang-up
F00
No error information
Description
Display appears when main unit and remote
controller codes are not matched.
Display appears when the drive has abnormal
temperature.
The power is turned off forcibly.
For 30 minutes after this, all key entries are
disabled. (Fan motor operates at the highest
speed for the first 5 minutes. For the
remaining 25 minutes, fan motor is also
stopped.) The event is saved in memory as
well.
This error is displayed when there are any
communication problems with the unit and the
equipments (TV, amplifier etc.) connected to
the unit by HDMI. (or when there is a problem
with the HDMI cable)
When authentication error occurs while the
equipments (TV, amplifier etc.) are connected
by HDMI. (or when there is a problem with the
HDMI cable)
HDMI cannot output because you are
connected to a model that does not support
copyright protection.
Displayed when communication error has
occurred between Main microprocessor and
Timer microprocessor.
Initial setting for error code in memory
(Error code Initialization is possible with error
code initialization and main unit initialization.)
16
Monitor Display
Automatic FL display
No display
"*" is remote controller code of the
main unit.
Display for 5 seconds.
No display
"U59 is displayed for 30 minutes.
No display
U72 display
error has been solved by Power
OFF/ON of connecting equipment
or by inserting/removing of HDMI
cable.
No display
U73 display
error has been solved by Power
OFF/ON of connecting equipment
or by inserting/removing of HDMI
cable.
No display
No display
No display
Displayed
[POWER] key is pressed.
No display
No display
disappears when
disappears when
is
left
until
the

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dmr--ez475vp