System Design Summary - Carrier 38BRC Product Data

60 hz air conditioner
Table of Contents

Advertisement

Detailed cooling capacities* continued
EVAPORATOR
AIR
85
Capacity
MBtuh†
CFM
EWB
Total
Sens‡
38BRC060-34, 35, 54 Outdoor Section With CC5A/CD5AW060 Indoor Section
72
64.4
31.5
67
59.3
39.8
1750
62
54.4
47.8
57
51.6
51.6
72
65.8
32.9
67
60.6
42.1
2000
62
55.3
50.8
57
53.4
53.4
72
66.8
34.2
67
61.3
44.2
2250
62
56.4
53.7
57
55.0
55.0
Indoor
Section
Size
CC5A/CD5AA
060
CC5A/CD5AW
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BN
060
CK5A/CK5BT
060
CK5A/CK5BX
060
F(A,B)4AN(F,B,C)
060
FB4ANB
070
FC4BN(F,B)
060
FC4BNB
070
40FKA/FK4CNB
006
* Detailed cooling capacities are based on indoor and outdoor unit at same elevation per ARI standard 210/240-94. If additional tubing length and/or
indoor unit is located above outdoor unit, a slight variation in capacity may occur.
† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835
Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of
indoor coil air per degree above 80°F (27°C).
** Unit kw is total of indoor and outdoor unit kilowatts.
NOTE: When the required data falls between the published data, interpolation may be performed.

System design summary

1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than
0.01-in. wc.
2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C).
3. Maximum outdoor operating air temperature is 125°F (51.7°C).
4. For reliable operation, unit should be level in all horizontal planes.
5. Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 50 ft, indoor coil below = 150 ft.
6. For interconnecting refrigerant tube lengths between 50 and 175 ft, consult the Residential Split System Long-Line Application
Guideline available from equipment distributor.
7. Crankcase heater required when interconnecting refrigerant tube length exceeds 50 ft.
8. If any refrigerant tubing is buried, provide a minimum 6-in. vertical rise to the valve connections at the unit. Refrigerant tubing
lengths up to 36 in. may be buried without further consideration. For buried lines longer than 3 ft, consult your local distributor.
9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector
provided.
CONDENSER ENTERING AIR TEMPERATURES °F
95
Capacity
Total
Total
MBtuh†
System
System
KW**
Total
Sens‡
KW**
5.03
61.7
30.5
5.55
4.94
56.8
38.7
5.46
4.87
52.1
46.7
5.38
4.84
49.8
49.8
5.34
5.15
63.0
31.8
5.67
5.06
58.0
41.0
5.58
4.97
52.9
49.6
5.47
4.94
51.5
51.5
5.45
5.26
63.9
33.1
5.78
5.16
58.9
43.2
5.69
5.09
53.9
52.3
5.59
5.05
53.2
53.2
5.58
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Capacity
Power
0.97
0.98
1.00
1.00
1.00
1.00
0.97
1.00
0.97
1.00
0.97
0.99
0.97
0.98
1.00
1.00
1.00
1.04
1.01
1.02
1.00
1.04
1.01
1.02
1.02
0.96
105
Capacity
Capacity
Total
MBtuh†
MBtuh†
System
Total
Sens‡
KW**
Total
58.9
29.4
6.12
55.9
54.2
37.6
6.02
51.5
49.7
45.5
5.91
47.2
48.0
48.0
5.88
46.0
60.0
30.7
6.25
56.9
55.3
39.9
6.14
52.4
50.5
48.3
6.02
47.9
49.5
49.5
6.00
47.4
60.9
32.0
6.36
57.3
56.1
42.1
6.26
53.2
51.4
50.8
6.14
48.9
50.9
50.9
6.12
48.6
Indoor
Section
Size
COILS + 58U(H,X)V100-20 VARIABLE-SPEED FURNACE
CC5A/CD5AA
060
CC5A/CD5AW
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BT
060
CK5A/CK5BX
060
COILS + 58U(H,X)V120-20 VARIABLE-SPEED FURNACE
CC5A/CD5AA
060
CC5A/CD5AW
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BT
060
CK5A/CK5BX
060
115
125
Capacity
Total
MBtuh†
System
Sens‡
KW**
Total
Sens‡
28.3
6.73
52.8
27.2
36.5
6.61
48.7
35.3
44.3
6.49
44.6
42.9
46.0
6.46
43.9
43.9
29.6
6.85
53.7
28.5
38.8
6.73
49.5
37.6
46.8
6.60
45.3
45.1
47.4
6.59
45.2
45.2
30.8
6.95
54.0
29.6
41.0
6.85
49.8
39.6
48.9
6.73
46.2
46.2
48.6
6.71
46.3
46.3
Cooling
Capacity
Power
0.97
1.00
0.97
0.97
0.97
1.00
0.97
1.00
0.97
0.97
0.97
1.00
Total
System
KW**
7.37
7.24
7.12
7.10
7.50
7.37
7.23
7.23
7.60
7.47
7.35
7.35
0.96
0.96
0.96
0.96
0.96
0.96
0.97
0.96
0.97
0.97
0.97
0.96