Needle Poisition Misalignment - Janome 4052lx Service Manual

Table of Contents

Advertisement

NEEDLE POSITION MISALIGNMENT
IF THE NEEDLE BAR MOVES SIDEWISE (ZIGZAG) WHEN THE PATTERN "
ZIGZAG WIDTH IS SET AT " 0 ", ADJUST AS FOLLOWS:
ADJUSTMENT PROCEDURE:
1. SET THE PATTERN SELECTOR DIAL AT "
FRONT COVER (SEE PAGE 7).
2. LOOSEN THE SETSCREW (A) AND GENTLY PUSH DOWN THE ZIGZAG ROD (C) TO THE BOTTOM OF
THE SLOT ON ZIGZAG REGULATOR ARM (B).
3. TIGHTEN THE SETSCREW (A), SWING THE ZIGZAG WIDTH REGULATOR ARM (B) AS SHOWN BY THE
ARROW
TO CHECK IF THE NEEDLE BAR DOES NOT MOVE SIDEWISE.
IF THE NEEDLE BAR STIL MOVES, LOOSEN THE SETSCREW (A) AND MOVE THE ZIGZAG WIDTH
ADJUSTING PLATE (D) UNTIL THE NEEDLE BAR STOPS MOVING SIDEWISE WHEN SWINGING THE
ZIGZAG WITH REGULATOR ARM.
4. ATTACH THE FRONT COVER.
ZIGZAG WIDTH ADJUSTING
PLATE (D)
ZIGZAG WIDTH ROD (C)
MECHANICAL ADJUSTMENT
", ZIGZAG WIDTH DIAL AT " 0 " AND REMOVE THE
SETSCREW (A)
20
" IS SELECTED AND THE
ZIGZAG WIDTH REGULATOR
ARM (B)