INSTALLATION INSTRUCTIONS FOR MODEL 42ZCBB OPTIONAL
WOODEN FLUSH MOUNT MANTEL FRONT (FF) (KIT#PAKDM42ZCBBFF)
"NOTE: Follow the framing instructions on page(s) 6 & 7. With the exception of the placement
of the 42ZCBB in the framed opening . The 42ZCBB must be placed with the front surface of
the appliance 1-9/16" out from the finished wall. This well allow the FF to set flush with the
front of the 42ZCBB".
CLEARANCES:
1. Sidewall Clearances:
combustible wall should not be less than 7". (See page 8, figure 4)
2. Ceiling Clearances: The ceiling height should not be less than 42" from the top of the firebox
opening.
INSTALLATION INSTRUCTIONS:
1. After removing the FF kit from its packaging follow any pre-installation instructions provided
with the kit.
2. Place the FF over the front of the 42ZCBB, centering the opening in the FF left to right with the
42ZCBB front.
3. Next you must secure the FF to the finished wall surface. You may use "L" brackets, screws or
finishing nails (not provided with the FF).
NOTE: If an unfinished FF kit is used, do not operate the appliance while finishing the wood or be-
fore the finish has dried properly.
TOP VIEW
6"
49-1/2"
FRONT VIEW
Clearances from the side of the firebox opening to any adjacent
42ZCBB
66-1/8"
59-1/8"
FINISHED WALL FACE
42ZCBB & FF FRONTS
ARE FLUSH.
10
REV.
DATE
BY
42ZCBB
1-9/16"
SIDE VIEW
D