New Buck Corporation 42ZCBB User Manual

Ventless firebox enclosure

Advertisement

Quick Links

BUCK STOVE MODEL 42ZCBB VENTLESS
FOR GAS-FIRED DECORATIVE TYPE UNVENTED ROOM
HEATERS FOR USE WITH OPTIONAL WOODEN FLUSH MOUNT
MANTEL (FF) AND OPTIONAL WOODEN SURROUND (WS)
MEETS THE MINIMUM DIMENSIONS REQUIRED
WARNING: If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
INSTALLER:
CONSUMER:
New Buck Corporation
P.O. Box 69
8000 Hwy. 226 South
Spruce Pine, NC 28777
FIREBOX ENCLOSURE
(UNIVERSAL BOX)
FOR USE ONLY WITH
A LISTED GAS-FIRED UNVENTED
DECORATIVE ROOM HEATER
NOT TO EXCEED
40,000 BTU/H
DO NOT BUILD A WOOD FIRE
Carefully review the instructions supplied
with the decorative type unvented room heater
for the minimum fireplace size requirement.
DO NOT INSTALL AN APPLIANCE IN
THIS FIREBOX UNLESS THIS FIREBOX
FOR THE INSTALLATION
Leave this manual with the appliance.
Retain this manual for future reference.
Revised: November 2004

Advertisement

Table of Contents
loading

Summary of Contents for New Buck Corporation 42ZCBB

  • Page 1 BUCK STOVE MODEL 42ZCBB VENTLESS FOR GAS-FIRED DECORATIVE TYPE UNVENTED ROOM HEATERS FOR USE WITH OPTIONAL WOODEN FLUSH MOUNT MANTEL (FF) AND OPTIONAL WOODEN SURROUND (WS) with the decorative type unvented room heater for the minimum fireplace size requirement. DO NOT INSTALL AN APPLIANCE IN...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Safety Information and Warnings ... 3 Installation ... 5 Firebox and Framing Dimensions (ZC) (FF) ... 6 Firebox Clearances (ZC) (FF) ... 7 Finishing Your Firebox ... 8 Mantel Profiles For Zero Clearance ... 9 Optional Wooden Flush Mount Mantel Front (FF)..…..…………………………………10 Optional Wooden Surround (WS)………………………………………………………...11 Producing Adequate Ventilation ...
  • Page 5: Safety Information And Warnings

    IMPORTANT: READ THIS OWNER’S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING TO ASSEMBLE, INSTALL, OPERATE, OR SERVICE THIS APPLIANCE (FIREBOX ENCLOSURE). Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! serviced.
  • Page 6 DO NOT USE A BLOWER INSERT, HEAT EXCHANGER INSERT, OR OTHER ACCESSORY NOT APPROVED FOR USE WITH THIS HEATER. THIS HEATER SHALL NOT BE INSTALLED IN A CONFINED SPACE UNLESS PROVISIONS ARE MADE FOR ADEQUATE COMBUSTION AND VENTILATION AIR. ”See Page 13, for “Producing Adequate Ventilation”. NOTE: THIS IS A VENTLESS FIREBOX ENCLOSURE (UNIVERSAL) FOR GAS FIRED DECORATIVE TYPE UNVENTED ROOM HEATERS.
  • Page 7: Installation

    Your New Buck Ventless Firebox Enclosure may be installed in Residential or *After-Market Manufactured Mobile Homes. This appliance may be installed in an *After Market Manufactured Mobile Home, where not prohibited by state or local codes. * (After Market: Completion of sale, not for the purpose of resale from the manufacturer). NOTE: See page 13 for “Producing Adequate Ventilation”.
  • Page 8: Firebox And Framing Dimensions (Zc) (Ff)

    FIREBOX AND FRAMING DIMENSIONS (ZC) & (FF) NOTE: SEE PAGE 10 IF AN OPTIONAL WOODEN FLUSH MOUNT MANTEL 18-15/16" 20 1/2" Figure 2 N O T E : Y O U R N E W CORPORATION VENTLESS ENCLOSURE IS EQUIPPED WITH A FACTORY INSTALLED CANOPY.
  • Page 9: Firebox Clearances (Zc) (Ff)

    FIREBOX CLEARANCES The firebox may be placed directly on a combustible floor, against a combustible wall at marked clearances, or on a raised wooden platform. If the firebox is to be installed on a raised wooden platform, the platform must be a continuous level surface. The firebox must be secured in place so it cannot shift positions.
  • Page 10: Finishing Your Firebox

    FINISHING YOUR FIREBOX There is a wide variety of finishing material available for your firebox from formal wall treatments with marble and mantels, to rustic wood paneling, stone or brick. IT IS IMPORTANT THAT THE BLACK FACE OF THE FIREBOX NOT BE COVERED WITH ANY TYPE OF COMBUSTIBLE MATERIAL.
  • Page 11: Mantel Profiles For Zero Clearance

    MANTEL PROFILES FOR VENTLESS FIREBOX ENCLOSURE (UNIVERSAL BOX) ZERO CLEARANCE CABINET MUST BE FOLLOWED COMBUSTIBLE MATERIALS STANDOFF FIGURE 5 MANTEL WIDTH (“A” inches) 10.0 12.0 3 1/2” 3/4” 42ZCBB 4” MANTEL CLEARANCES MANTEL HEIGHT (“B” inches above firebox opening) 14.0 14.0 14.0 16.0 3” CANOPY...
  • Page 12: Optional Wooden Flush Mount Mantel Front (Ff)

    1. After removing the FF kit from its packaging follow any pre-installation instructions provided with the kit. 2. Place the FF over the front of the 42ZCBB, centering the opening in the FF left to right with the 42ZCBB front.
  • Page 13: Optional Wooden Surround (Ws)

    INSTALLATION INSTRUCTIONS FOR MODEL 42ZCBB OPTIONAL WOODEN SURROUND (WS) (KIT# PAKDM42ZCBB) CLEARANCES: 1. Sidewall Clearances: Clearances from the side of the firebox opening to any adjacent combustible wall should not be less than 7". See Figure 4 2. Ceiling Clearances: The ceiling height should not be less than 42" from the top of the firebox opening.
  • Page 14 After assembling the WS you must insert the 42ZCBB. It is best to insert the 42ZCBB from the rear of the WS, this gives you more area to hold the 42ZCBB and reduces the risk of scratching the sur- face of the front area of the base (hearth) area. Flush and center the 42ZCBB’s front in the WS.
  • Page 15: Producing Adequate Ventilation

    PRODUCING ADEQUATE VENTILATION NOTICE: Information on provisions for adequate combustion and ventilation air are located in the unvented room heater ‘s installation instructions. The unvented room heater’s instructions must be followed exactly. This section is used for residential installation or mobile home installation. UNCONFINED SPACE: An unconfined space has a minimum air volume of 50 cubic feet for each 1,000 BTU/Hr (4.8m Kw) input rating of all appliances in the space (Cubic feet equals Length x Width x Height of space).
  • Page 16 Add the BTU/Hr of all fuel burning appliances in the space. Vent-Free Heater Gas Water Heater* Gas Furnace Vented Gas Heater Gas Fireplace Logs Other Gas Appliance* Total Example: Gas water heater Vent-free heater Total * Does not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
  • Page 17: Ventilation Air From Indoors

    VENTILATION AIR VENTILATION AIR FROM INSIDE BUILDING This fresh air would come from an adjoining unconfined space. When venting to an adjoining space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see Options 1 and 2, Figure 6).
  • Page 18: Ventilation Air From Outdoors

    VENTILATION AIR FROM OUTDOORS Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 4.3, “Air For Combustion and Ventilation”...
  • Page 19: Optional Blower Installation

    (residence) in order to have electricity to operate the blower motor. If the receptacle hasn’t been wired in during installation of the 42ZCBB you may need to contact a licensed electrician. The Model 42ZCBB also has a thermostat and wires and an ON/OFF switch standard on all units.
  • Page 20: Wiring Diagram

    WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED OF HIGH SURFACE TEMPERATURE AND SHOULD STAT AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE APPLIANCE. WARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON OR NEAR THE APPLIANCE.
  • Page 21: Replacement Parts

    3. REAR REFRACTORY AND SIDE REFRACTORY 2 PIECES PER UNIT 6. CANOPY 7. DOOR KIT (PART# MAZCBBDOORS) PARTS MAY BE OBTAINED THROUGH YOUR LOCAL NBC DEALER. ABSENCE OF A DEALER, PLEASE CONTACT NEW BUCK CORPORATION AT P.O. BOX 69, 8000 HWY 226 SOUTH, SPRUCE PINE, NC 28777. DESCRIPTION MOTOR...
  • Page 22: Warranty

    NEW BUCK CORPORATION We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We offer no other warranty, expressed or implied. LIMITED WARRANTY VENTLESS FIREBOX ENCLOSURE New Buck warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated, and maintained in accordance with all applicable instructions.