Tools For Installation - New Buck Corporation 91 User Manual

Fireplace insert & freestanding
Hide thumbs Also See for 91:
Table of Contents

Advertisement

CLOSE CLEARANCE INSTALLATIONS (in inches)
Close clearance installation is possible by using the following brands of black, double-wall chimney pipe. (See
Figure 4 and Figure 5 for clearances.)
1. Simpson Dura-Vent double wall chimney connector "Type DVL" and 8" Simpson Dura-Vent 2100
"Type DP" chimney
2. 8" Security Type DL double wall connector and 8" Security Type "ASHT" High Temp Chimney.
3. 8" Selkirk Metal Bestos Model "DS" double wall connector-8" Selkirk Metal Bestos Model SSII type HT
Chimney System.
4. 8" Metal Fab type "DW" double wall connector - 8" Metal Fab 2100
5. 8" Air Jet
FIGURE 4

TOOLS FOR INSTALLATION

Drop Cloth
Electric Drill with 3/32" drill bit
5/16" combination wrench
5/16" magnetic socket chuck adapter, 5/16"
wrench (box or socket) or adjustable wrench
Pencil
Socket Set
Level
Tape Measure
Screw Driver
Wall Exit into Metal Tee-Box (Using
Single Wall Pipe)
1. Mark the plumb line on the wall directly
behind the center of the heater. (See Figure
6.)
NOTE: When using #24 ga. min. blued or black
steel
pipe, maintain 18" between pipe and
ceiling.
2. Place the vertical portion of the heater pipe
and the elbow in position and project a point
onto the plumb line level with the center of
the elbow.
o
HT chimney.
FIGURE 5
1/4" Rise Per. FT.
FIGURE 6
o
HT