Installation Of Indoor And Outdoor Unit - Hitachi RAS-50FH7 Service Manual

Hide thumbs Also See for RAS-50FH7:
Table of Contents

Advertisement

Figure showing the installation of Indoor and Outdoor unit
MODEL RAS-50FH7 / RAC-50YH7
above 100mm
above 700mm
Be sure to
completely seal
any gap with putty.
above 200mm
)
(
above 50mm when
installed on the
ceiling of balcony
above 50mm
above 100mm
2,300mm or more
Plug
above 100mm
give clearance as
wide as possible
above 200mm
– 6 –
2
1
above 100mm
The indoor piping should be
insulated with the enclosed
insulation pipe. (If the insulator
is insufficient, please use
commersial products).
The difference in height
G
between the indoor and
outdoor unit should be kept
max 10m.
The connecting pipe, no
G
matter big or small, should
all
be
insulated
insulation pipe and then
wrapped with vinyl tape. (The
insulator will deteriorate if it
is not wrapped with tape).
The connection of insulated
drain hose.
Please use insulated drain
hose for the indoor piping
(commercial product).