YX GoIP User Manual CONTENT INTRODUCTION ................... 1 Overview ......................1 Glossary ......................1 EQUIPMENT INFORMATION ............... 2 Appearance ......................2 Hardware ......................2 Software ......................3 Function and Features ..................3 EQUIPMENT INSTALLATION ..............4 Network Setup ..................... 4 Equipment IP Address ..................
Page 3
YX GoIP User Manual Landing from IP to Mobile Network ..............39 Access from Mobile Network to IP ..............40 FAQ ......................41 How to designate a port for outbound call ............41 APPENDIX 1 ....................43 第 iii 页...
It enables direct routing between IP, digital, analog and mobile networks. GoIP Gateway is now used more and more for telephone carriers to land their IP calls to mobile network. In those areas where fixed line services are unavailable or much more expensive than the mobile cost, GoIP Gateway is an irreplaceable alternative.
YX GoIP User Manual 2 Equipment Information 2.1 Appearance The following figure shows the front view of YX GoIP Gateway. Figure 2.1: Front View The following figure shows the rear view of YX GoIP Gateway. Figure 2.2: Rear View 2.2 Hardware The following table shows the hardware information for YX GoIP Gateway.
Built-in Http Server Firmware SIP Client DHCP Client DHCP Server PPPoE 2.4 Function and Features This chapter introduces the overall function and features of YX GoIP Gateway. Hot-line call Dial pattern Dial prefix manipulation Phone book White list YX Tech...
YX GoIP User Manual 3 Equipment Installation This chapter describes how to install a new GoIP Gateway to a physical network environment, how to initialize it and start it in a proper way. 3.1 Network Setup Network is a prerequisite to install GoIP Gateway. The following figure shows the topology of LAN with a VoIP Gateway connected.
5) Plug in the GoIP Gateway. 3.4 LED Indicators There are a set of LED lights in the front of GoIP Gateway. Lights will be on or glittering when the GoIP Gateway is power on and running. The following table describes various meanings of status corresponding to LED lights in different display color.
YX GoIP User Manual 4 Web Settings This chapter describes how to set up GoIP Gateway through Web Page. There is a built-in web server which can be accessed at URL: http://GATEWAY_IP/, while GATEWAY_IP is the WAN IP address of the GoIP Gateway, such as 192.168.1.67.
YX GoIP User Manual 4.2 Basic Settings Basic Settings will be described in this paragraph. The most frequently modified parameters and most of the individual parameters are listed in this page. SIP Server Settings is for SIP communication with IP network. Fields are specified as following: Protocol Mode: Specify SIP client working mode.
YX GoIP User Manual Registration/Point-to-Point. If set to Registration, SIP client will send registration messages to SIP server. Encryption Method: Specify the encryption method for messages between SIP server and SIP client. SIP Server IP: Specify the IP of SIP server.
Page 12
Settings page, all the inputs here can be left empty and the default setting will apply to all the SIP accounts. For example, if an account GOIP-03 is set with password 888888 in Basic Settings page and all the SIP accounts here are left empty, the combination of GOIP-03 and 888888 will be used for all SIP accounts to register to SIP Server.
The screenshot below shows the operation mode to set GoIP port properties. The columns are specified as following: Port No: The GoIP Gateway mobile port. Each port contains one or more card slots. Port No starts from 1 to 8.
Page 14
The any other idle port may be either on the same GoIP Gateway or on another GoIP Gateway which keeps reporting its port status to a Notification Server.
The screenshot below shows the operation mode to set IMEI for each card inserted in GoIP Gateway port. Fields are specified as following: Port No: The GoIP Gateway mobile port. Each port contains one or more card slots. Port No starts from 1 to 8. YX Tech...
Page 16
A group of IMEIs which are increased by 1 in numeric sequence can be set for one or all card(s) on one or all GoIP Gateway mobile port(s). If a card on a port is assigned with a group of IMEIs, it will randomly use any of the IMEI in group to communicate with mobile base.
Server IP: Specify the IP of server to which the SMS is sent. If set to empty, the SMS will be sent to SIP server. SMS Coding: Specify the SMS coding when SMS is sent to through SIP protocol. The screenshot below shows the operation mode to send SMS through the GoIP Gateway. YX Tech 12/21/2012...
YX GoIP User Manual 1) Select a module. The module here means GoIP mobile port and the SMS is sent out through the card which is in service on this port. 2) Input the receivers separated by semi-colon. 3) Input SMS content and click button Send to send out the SMS.
Page 19
YX GoIP User Manual Smart Check: Specify whether enable the smart check for cards in card slot or not. If set to Enabled, those card slots without card inserted will be skipped when system is scanning for available cards. SMS Receiver for Warning: Specify the receiver mobile number to receive the warning SMS for card lock or switch.
Page 20
YX GoIP User Manual The following is to set condition of accumulated bridges. Fields are specified as following: Enable or Not: Specify whether enable this condition. If set to Enable, the accumulated number of bridges will be used as a condition for system to check.
Locking Duration: Specify how long the card will be locked. 4.4.5 AT Command The screenshot below shows the operation mode to send AT command to GoIP Gateway. YX Tech...
After send a command, a re-enter of this page is needed to see the command response. 4.4.6 Billing The screenshot below shows the operation mode to set GoIP billing. A smart billing server for mobile port is embedded in GoIP Gateway. Fields are specified as following: GoIP Billing: Specify whether enable GoIP billing or not.
Page 23
Enabled. USSD Check: Specify whether enable to get balance through USSD check or not. This field takes effect only when GoIP Billing is set to Enabled. Save Balance: Specify whether need to save the current balance to card periodically.
Page 24
Add/Edit. Value Add means the data is new while value Edit means the data is old. Device Port: Specify the GoIP mobile port on which this tariff will take effective. If set to *, this tariff record will apply to all ports. The single port number can be an integer from 1 to 8.
YX GoIP User Manual Click button Submit on the right to save the new data record. Edit All the records are displayed in list. Two operations are provided on the right of each record. Click Edit to expand the current data record to Data Detail Area which is above the Data List.
Page 26
YX GoIP User Manual Add New Click button Add New to expand the data input area to add new data. Fields are specified as following: Data status: Mark the status of current data record. Option values are Add/Edit. Value Add means the data is new while value Edit means the data is old.
YX GoIP User Manual Another shortcut button is also provided on the top right of Data List to delete multiple selected records in batch. A message box will be popped for confirmation of batch delete. Note: The operations Add New/Edit/Delete/Batch Delete mentioned in the following paragraph are almost the same as phone book.
YX GoIP User Manual Fields are specified as following: Prefix: The original prefix in phone number. Manipulated Prefix: Specify the digits with which the value specified by Prefix will be substituted. Take the value in screenshot as an example, the prefix 9999 in dialed number will be substituted with 0.
LAN port is used for PC to connect GoIP Gateway directly without any other route. The default LAN IP is 192.167.1.1. If a PC is connected to LAN port of a GoIP Gateway, it needs the same sub-network to access GoIP Gateway directly.
For example, if field Web Port is set to 8080 and a PC is connected to the LAN port of GoIP Gateway with IP 192.167.1.10, the web pages then should be accessed through URL: http://192.167.1.10:8080/ from this computer.
Asia are shown in the screenshot above for reference. The screenshot below shows the operation mode to set codec priority. Three codec types are provided to adjust GoIP Gateway to different network environment. The top codec will be chosen to use by default. G729 uses the least bandwidth.
Page 32
The columns are specified as following: Port: The analog port sequence from 1 to 32. Type: Option values are FXO/FXS. (GoIP port is currently treated as FXO.) Enable: Specify whether enable or disable this port. Hot-line: Specify a phone number for short. If the port type is FXO, any extern call to this port will be redirected to this hot line.
Page 33
YX GoIP User Manual IP TOS: Specify whether enable IP TOS or not. Don’t send # to PSTN: Specify whether need to remove the last digit # to PSTN if the last digit of numbers is #. If set to Enable, the last # will be removed.
YX GoIP User Manual Rate: Specify rate. Option values 14400/12000/9600/7200/4800/2400. 4.7 System Settings System Settings include: User Management Remote Management System Update These sub topics will be introduced separately below. 4.7.1 User Management The screenshot below shows the operation mode to manage system user.
Network must be available for the gateway to communicate with ETMS Server. If ETMS is enabled and correctly set, the GoIP will register to EMTS server and set up the connection between itself and ETMS server. Administrator can login ETMS server and monitor all the registered GoIP Gateways.
YX GoIP User Manual Enable ETMS: Specify whether enable ETMS registration or not. Option values are Enabled/Disabled. ETMS Server IP/Domain: Specify the ETMS Server address. Either IP or Domain is a valid input. Port: Specify the ETMS server port. Expiration Period: Specify the expiration period for registration to ETMS server.
Note: LED A/B/C/D displays in accordance with the lights on the front board of GoIP Gateway. Port 1 to 8 relate to the physical port of GoIP Gateway. The following table shows the relationship between LED color and port status.
YX GoIP User Manual The screenshot below shows the port status in detail. The status columns are specified as following: Port No: The physical port sequence from 1 to 8. Provider: The mobile provider that system detects. Module Detected: Specify whether port module has been detected or not.
The status columns are specified as following: Port No: The physical port sequence from 1 to 8. Type: FXO or FXS. Currently GoIP is regarded as FXO. Status: Specify the call status. Balance: Specify the current balance of the card in this port.
YX GoIP User Manual 4.8.4 Call Statistics The screenshot below shows the call statistics information for analysis. The status columns are specified as following: Port No: The physical port sequence from 1 to 8. Calls: Specify the total calls made out from this port since the last start up of system.
A total summary is displayed at the bottom of the table. 4.9 Save and Reboot Generally, any modification should require the reboot of GoIP Gateway to bring the modification into effect. However, single Save without Reboot is also frequently used to save the modifications which will be effective on next reboot of GoIP Gateway.
This chapter presents some typical used scenarios for reference. 5.1 Landing from IP to Mobile Network GoIP Gateway is now used more and more for telephone carriers to land their IP calls to mobile network. It plays the role of converting IP telephone signal to GSM telephone signal, relaying the media stream between IP network and Mobile network.
YX GoIP User Manual 5.2 Access from Mobile Network to IP GoIP Gateway can be used as the access from mobile network to IP. Any call made to the mobile card inserted into GoIP Gateway will be routed to IP network and connected to Softswitch server.
Sometimes the outbound call to mobile network is required to be called through one or any one of a designated group of GoIP Gateway ports in order to reduce the cost. Here is an example to show you how to complete the settings for GoIP Gateway to make outbound call through a designated port.
Page 45
YX GoIP User Manual c) The outbound call whose destination is prefixed with 888, such as 88813512345678 will be routed to SIP Port 8. YX Tech 12/21/2012...
Need help?
Do you have a question about the GoIP and is the answer not in the manual?
Questions and answers