7.14 Forced Auto function
Select forced auto function with the forced auto button or the switch.
In forced auto status the A/C operates at remote control mode with a set temp. of 24℃.
7.15 Timer Function
7.16 Economic Running
7.16.1
The economic running function is available at cooling, heating or auto mode.
7.17
Cooling: The set temperature rise 1℃ per hour. Two hours later, the set temperature will maintain
as a constant and the fan speed is kept at low speed.
7.18 Heating:
The set temperature decrease 1℃ per hour. Two hours later, the set temperature will
maintain as a constant and the air circulation is kept at low speed (Cold air proof function takes
precedence over all).
7.19 Auto: The economic running function operates in accordance with selected running mode by auto mode.
7.20 uto restart function: In case of a sudden power failure, this function automatically sets the unit to
previous settings before the power failure when power returns.