SERVICE TEST PROGRAM
QUARTZ
TUNER
TEST
TEST
N
TUNER
Button pressed?
Button pressed?
Y
Display Tuner Version
Display shows
"ccc"
Output at (Front Display Board)
pin 19 of uP = 2048Hz
N
TUNER
Button pressed?
Button pressed?
Service frequencies are
copied to the RAM (see Table 1)
Tuner works normally except:
Display shows
PROGRAM button
Output at (Front Display Board)
pin 19 of uP = 2,929.6875Hz
N
Disconnect
Mains cord ?
Button pressed?
Y
Service Mode left
East Eur. Extended-band
Europe
East Eur.
"EAS"
PRESET
"EUR"
"EAS"
65.81MHz
87.5MHz
1
87.5MHz
87.5MHz
108MHz
2
108MHz
108MHz
74MHz
3
531kHz
531kHz
87.5MHz
1700kHz
4
1602kHz
1602kHz
531kHz
5
558kHz
558kHz
1602kHz
1500kHz
6
1494kHz
1494kHz
558kHz
7
153kHz
87.5MHz
1494kHz
87.5MHz
8
279kHz
87.5MHz
98MHz
87.5MHz
9
198kHz
87.5MHz
70.01MHz
87.5MHz
10
98MHz
87.5MHz
65.81MHz
87.5MHz
11
87.5MHz
98MHz
Table 1
Note: * Depending on the selected grid frequency (9 or 10kHz)
By holding the TUNER and R buttons depressed while switching on the Mains supply, one
of the undermentioned features will be activated:
- the tuning grid frequency is toggled between 9kHz and 10kHz for the Oversea (/21) version.
- the extended FM1 (65.81MHz - 74MHz) is toggled on and off for East Eur. (/34) version.
3-4
To start service test program
hold
depressed while
plugging in the mains cord
Display shows the
ROM version
"S-Vyy"
(Main menu)
SERVICE
PLAY MODE
N
O
STANDBY-ON
Button pressed?
Y
Y
Set is in Service PLAY Mode.
32K
In case of failures, error
codes according to Table 2
will be displayed.
The Service Play Mode is intended to
O
N
detect and identify the failures in the CD Mode.
In this mode the electronics will still function
even when an error is detected so that
repair activities can be carried out.
Y
12M
9
N
Error Description
Error code
Y
E1000
Focus Error
Triggered when the focus could not be found within a certain time when starting up the CD
or when the focus is lost for a certain time during play.
E1001
Radial Error
Triggered when the radial servo is off-track for a certain time during play.
E1002
Sledge In Error
The sledge did not reach its inner position (inner-switch is still close) before approximately
6 Sec. have passed by. Inner-switch or sledge motor problem.
USA
Oversea
E1003
Sledge Out Error
"USA"
"OSE"
The sledge did not come out of its inner position (inner-switch is still open) before approximately
250 mSec. have passed by. Inner-switch or sledge motor problem.
87.5MHz
E1005
Jump-offtrack error
108MHz
108MHz
Triggered in normal play when the jump destination could not be found within a certain time.
When this error occurred, software will try to recover by initiating the jump command again.
530kHz
531/530kHz*
If it is recoverable, the disc will continue to play.
1602/1700kHz*
E1006
Subcode Error
560kHz
Triggered when a new subcode was missing for a certain time during play.
558/560kHz*
1494/1500kHz*
E1007
PLL Error
The Phase Lock Loop could not lock within a certain time.
98MHz
87.5MHz
Turntable Motor Error
E1008
87.5MHz
Generated when the CD could not reached 75% of speed during startup within a certain time.
Discmotor problem.
87.5MHz
E1020
Focus Search Error
87.5MHz
The focus point has not been found within a certain time.
98MHz
The carousel switch is not open within certain time. This can happen when either the switch is
E1070
defective and closed all the time, or when the carousel is blocked when located exactly at a
disc position.
E1071
The carousel position switch did not close within a certain time. This can happen when the
switch is defective and never closes electrically, or when the carousel is blocked in between
two disc positions. The time-out is approximately 5 Sec.
E1079
The drawer could not enter the inside position is opening again. This can be caused because
the drawer is blocked by something and cannot go fully inside, or the drawer switch is defective
and does not close.
Æ ™
& Aux
S refers to Service Mode
V refers to Version
yy refers to Software version number of the µProcessor
(counting up from 01 to 99)
N
Figure 1
Figure 2
Table 2
3-4
DISPLAY
TEST
N
2
Button pressed?
Y
Display shows Figure 1 and
switch all LEDs on (except ECO
POWER & VU Volume LEDs),
and full VU deflection.
N
2
Button pressed?
Y
Display shows Figure 2
and switch alternate LEDs on
(see Table 3),
and partial VU deflection.
N
9
Button pressed?
Y
LEDs
FW-C500 , FW-C550
FW-C700 , FW-C720
FW-P750
FW-C780
DISC 1
On
On
On
DISC 3
On
On
On
TAPE
On
On
On
TUNER
On
On
On
CENTRE
On
SURROUND LEFT
On
STEREO RIGHT
On
VAC
On
On
On
DBB
On
On
VU BACK LIGHT
On
On
On
VU VOLUME
On
On
On
Various
Table 3
other Tests
TEST
Activated with
ACTION
R
EEPROM TEST
A test pattern will be sent to the EEPROM.
"PASS" is displayed if the uProcessor read
back the test pattern correctly, otherwise
9 to Exit
"ERROR" will be displayed.
Q
EEPROM FORMAT
Load default data. Display shows "NEW"
TEST
for 1 second.
Caution!
All presets from the customer will be lost!!
ROTARY
Rotary
Display shows value for 2 seconds.
ENCODER TEST
Volume Knob
Values increases or decreases in steps of 1
or
until 0 (Min.) or 40 (Max.) is reached.
Jog Shuttle Knob
Disconnect
LEAVE SERVICE
mains cord
TESTPROGRAM
Mini 2001 FW-C5xx/7xx Service Test Program (dd wk0046)

Advertisement

loading

This manual is also suitable for:

Fw-c780/22Fw-c780/37