MX8000-3EX Installation and Operation Guide
ADEMCO Model Number
Item
Three Line card
MX8000–LC3
CPU, PS, User
MX8000
Interface
Backup battery
Acquire from a local retailer
(See Section 3.12 for
installation.)
Printer cable
Acquire from a local retailer
SBUS cable
Acquire from a local retailer
Rack-mounting
Acquire from a local retailer
cabinet
Blank filler panels
Acquire from a local retailer
Parallel printer
Acquire from a local retailer
1.3
Formats Compatible with the MX8000–3EX
The MX8000–3EX receiver is compatible with all ADEMCO communicators.
Table 1–2 shows the formats that the MX8000–3EX receiver can decode and the handshake frequency
groups that accommodate that format (see Section 5.4 for line device programming). Each line device can
decode every format listed below. Setting the handshake order only prioritizes the type of communication
done by each line device. Section 6 of this manual describes the formats in greater detail.
Important Note: When selecting a reporting format and using an automation computer, it is essential that
you check Table 8–2: Reporting Formats and Automation Protocol Support to verify that the reporting format
selected is supported by the automation protocol that will be used.
REPORTING FORMAT
3/1, 3/1 Ext
3/1 Even Round
3/1 w/cksum
3/1 Ext w/cksum
3/2
3/2 Even Round
3/2 w/cksum
4/1, 4/1 Ext
4/1 Even Round
4/1 w/cksum
4/1 Ext w/cksum
4/2
4/2 Even Round
4/2 w/cksum
BFSK
FSK0/FSK 80
FSK1/FSK 81
FSK2/FSK 86
ITI CareTaker+, SecurityPro 4000
ITI Commander
ITI Commander 2000, LifeGard
ITI RF Commander, Harbor Gard
ITI SX-V
1–2
Table 1–1: Optional Accessories for the MX8000–3EX Receiver
(if applicable)
CPU-EX
Table 1–2: Formats Compatible with the MX8000–3EX
PPS or CPS
10, 20, or 40 PPS
10, 20, or 40 PPS
10, 20, or 40 PPS
10, 20, or 40 PPS
10, 20, or 40 PPS
10, 20, or 40 PPS
10, 20, or 40 PPS
10 PPS
10 PPS
10 PPS
10 PPS
10 PPS
10 PPS
10 PPS
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Description/Comments
The 3 line card monitors the phone lines, detects ring and processes the
message from the communicating panel.
The CPU, Power Supply, User Interface Assembly contains the VFD, main
processing board, and receiver power supply.
An approved 12VDC 7AH battery such as a Powersonic PS-1270 that will
provide a minimum 4 hours of backup power during an AC power loss.
A standard 25-pin cable used to connect the MX8000
external parallel printer.
A standard 4-wire RJ-11 reverse cable such as a Digi-Key H2642-14-ND that
is used to connect the receivers together for receiver linking.
Used to rack mount the MX8000
Used to fill up any unused cabinet spaces.
The ADEMCO MX8000
–3EX
parallel printer such as the Okidata Microline 320 to generate a hardcopy of
report history.
REPORTING FORMAT
ITI UltraGard
Radionics Modem II
Radionics Modem IIE
SIA DCS
SX-III, SX-IVA
SX-IVB
Varitech FSK 4/1
Varitech FSK 4/2
Acron Touchtone w/ 3-digit
account
Acron Touchtone w/ 4-digit
account
ADEMCO 4/1 w/cksum
ADEMCO 4/2 w/cksum
ADEMCO High Speed
ADEMCO High Speed w/cksum
Contact ID®
Contact ID®10
FBII 4/3/1
FBII 4/3/1 w/cksum
FBII Superfast
Westec 970
Westec 1000/2000/3000
–3EX
–3EX
receiver.
receiver requires a UL approved dot matrix
receiver to an
PPS or CPS
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
10 CPS
10 CPS
10 PPS
10 PPS
10 CPS
10 CPS
10 CPS
10 CPS
10, 20, or 40 PPS
10, 20, or 40 PPS
10 CPS
10 CPS

Advertisement