Separate Auger Housing From Frame - Ariens Compact 24 LE Service Manual

Compact series
Hide thumbs Also See for Compact 24 LE:
Table of Contents

Advertisement

SEPARATE AUGER HOUSING FROM
FRAME
NOTICE: Save all hardware for reinstallation.
1.
Stop engine, remove key and wait for all moving parts
to stop and for hot parts to cool.
2.
Disconnect spark plug wire from engine.
3.
Remove cable hanger from chute rotation rod.
See Figure 6.
4.
Remove hardware retaining chute gear cover to chute
pedestal and remove cover.
5.
Remove spring clip from chute rotation rod and
remove rod.
1
1. Tapping Screw
2. Chute Gear Cover
3. Spring Clip
4. Chute Rotation Rod
See Figure 7.
6.
Remove hairpin and sleeve bushing from deflector
arm under dash panel.
7.
Remove cable from deflector arm and remove cable
snap from deflector anchor.
8.
Reinstall hairpin so it is not misplaced.
2
4
3
Figure 6
1
1. Sleeve Bushing
2. Hairpin
3. Cable Snap
4. Deflector Arm
5. Deflector Anchor
See Figure 8.
9.
Loosen, but DO NOT remove hardware securing belt
cover to unit and remove belt cover.
1
2
1. Belt Cover
2. Tapping Screw
EN – 10
3
5
Figure 7
Figure 8
4
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Compact 24 letCompact 22 l ce

Table of Contents