Sony HCD-DZ7T Service Manual page 26

Hide thumbs Also See for HCD-DZ7T:
Table of Contents

Advertisement

HCD-DZ7T
QQ
3 7 63 1515 0
DVD SECTION
12-1. General Description
The IOP measurement allows you to make diagnosis and adjustment
simply by using the remote commander and monitor TV. The
instructions, diagnosis results, etc. are given on the on-screen display
(OSD).
Be sure to execute the IOP measurement when a BU (Base Unit) is
replaced.
12-2. How To Enter Test Mode
and A buttons simultaneously, turn
x
While pressing the
VOLUME control in the direction of (+) with the DVD player in
power on.
The Test Mode starts, displayed "SERVICE IN" on this model
display then the menu shown below will be displayed on the TV
screen.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name
: BS5K_ XX
IF-con
: V
er. XX.XX (XXXX)
Syscon
: Ver.
X.XXX
TE
L 13942296513
*1: Changes depending on destination
The menu above is the Remocon Diagnosis Menu screen which
consists of five main functions. At the bottom of the menu screen, the
model name and IF-con version. To exit from the Test Mode, press
the ?/1 button on the remote commander.
12-3. Executing IOP Measurement
In order to execute IOP measurement, the following standard
procedures must be followed.
(1) In power on, while pressing the
simultaneously, turn the VOLUME control in the direction
of (+).
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version information
Model Name
: BS5K_ XX
IF-con
: Ver. XX.XX (XXXX)
Syscon
: Ver. X.XXX
*1: Changes depending on destination
www
.
26
http://www.xiaoyu163.com
*
1
and A buttons
x
*
1
x
ao
y
i
http://www.xiaoyu163.com
8
(2) Select "2. Drive Manual Operation" by pressing the 2 button
on the remote commander. The screen will appear as shown.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time adjust
0. Return to Top Menu
(3) Select "3. Manual Adjustment" by pressing the 3 button on
the remote commander. The screen will appear as shown.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
O o Change Value
[RETURN] Return to previous menu
(4)Select "6.IOP" by pressing the 6 button on the remote
Q Q
commander.
3
6 7
1 3
(5) Wait until a hexadecimal number appear.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. 52:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
O o Change Value
[RETURN] Return to previous menu
(6) Convert each data from hexadecimal to decimal using
conversion table.
(7) Please find the label on the rear of the BU (Base Unit).
The default IOP value is written in the label.
(8) Subtract between these two values.
(9) If the remainder is smaller than 93 (decimal), then it is OK.
However if the value is higher than 93, then the BU is defective
and need to be change.
(10) Press the RETURN button on the remote commander to
u163
return back to previous menu.
.
(11) Press the 0 button on the remote commander to return to
Top Menu.
2 9
9 4
2 8
1 5
0 5
8
2 9
9 4
m
co
9 9
2 8
9 9

Advertisement

Table of Contents
loading

Table of Contents