Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WATER INLET VALVE SOLENOIDS
COLD (BLUE)
Terminals
Refer to page 4-2 for the procedure for servic-
ing the water inlet valves.
1.
Unplug washer or disconnect power.
2.
Disconnect the wires from the water inlet
valve solenoid terminals.
3.
Set the ohmmeter to the R x 100 scale.
4.
Touch the ohmmeter test leads to the hot
and cold water inlet valve solenoid termi-
nals. The meter should indicate between
890 and 1090 Ω for both solenoids.
WARNING
Electrical Shock Hazard
DRIVE MOTOR CAPACITOR
HOT (RED)
Refer to page 4-14 for the procedure for servic-
ing the drive motor capacitor.
1.
2.
3.
4.
5-2
Capacitor Connectors
Unplug washer or disconnect power.
Disconnect the wires from the capacitor
terminals.
Set the ohmmeter to the R x 1K scale.
Touch the ohmmeter test leads to the
capacitor terminals. The meter should
momentarily deflect toward 0 Ω and then
reverse direction toward infinity.