Power problems
The server does not power on.
The system does not power off.
Microprocessor problems
The server emits a continuous
tone during POST.
Memory problems
The amount of memory displayed
is less than the amount of
memory installed.
Verify that:
1. The power cables are properly connected to the server.
2. The electrical outlet functions properly.
3. The type of memory that is installed is correct.
4. If you just installed an option, remove it, and restart the server. If the server
now powers on, you might have installed more options than the power supply
can support.
5. The LEDs on the power supply are on.
If the problem remains, call for service.
Verify if you are using an ACPI or non-ACPI operating system.
If you are using a non-ACPI operating system:
1. Press Ctrl+Alt+Delete.
2. Turn off the system by using the power-control button.
If the problem remains or if you are using an ACPI aware operating system, call
for service.
The startup (boot) microprocessor is not working properly.
Verify that the startup microprocessor is seated properly. If it is, replace the
startup microprocessor.
If the problem remains, call for service.
Verify that:
v The memory modules are seated properly.
v You have installed the correct type of memory.
v If you changed the memory, you updated the memory configuration with the
Configuration/Setup Utility program.
v All pairs or quads of memory on the DIMMs are enabled. The server might
have automatically disabled a DIMM pair or quad when it detected a problem,
or a DIMM pair or quad might have been manually disabled.
Look in the POST error log for error message 289:
v If the DIMM was disabled by a system-management interrupt (SMI), replace the
DIMM.
v If the DIMM was disabled by POST:
1. Start the Configuration/Setup Utility program.
2. Enable the DIMM.
3. Save the configuration and restart the server.
v If you continue to get this error, replace the DIMM.
If the problem remains, call for service.
Suggested action
Suggested action
Suggested action
Chapter 5. Solving problems
39