IBM 8685 xSeries 255 Installation Manual page 25

Xseries
Hide thumbs Also See for 8685 xSeries 255:
Table of Contents

Advertisement

Configuration/Setup Utility program assigns the Hot Spare Memory bank
according to your server configuration. If your server has a two-way interleaved
configuration, the Hot Spare Memory bank becomes the DIMMs in connectors D2
and D8. If your server has a four-way interleaved configuration, the Hot Spare
Memory bank becomes the DIMMs in connectors D1, D2, D7, and D8. See the
User's Guide on the IBM xSeries Documentation CD for further details about
enabling the Hot Spare Memory feature.
When you install DIMMs, install them in the order listed in Table 2.
Table 2. DIMM installation order
Interleaving
Number of DIMMs
Two-way
Two-way
Two-way
Four-way
Four-way
Four-way
Complete the following steps to install a DIMM.
1. Review the information beginning with "Safety" on page v through "Handling
static-sensitive devices" on page x.
2. Turn off the server and disconnect all power cords and external cables.
3. Remove the top cover.
4. Remove the air baffle.
5. Remove the memory-board assembly from the server and open the airflow
guide.
Install DIMMs in these connectors
2
D2, D8 (standard)
4
D2, D8 (standard) (Hot Spare memory
bank for two-way interleaving)
D4, D10
6
D2, D8 (standard) (Hot Spare memory
bank for two-way interleaving)
D4, D10
D6, D12
4
D2, D8, D1, D7
8
D2, D8, D1, D7 (Hot Spare memory bank
for four-way interleaving)
D4, D10, D3, D9
12
D2, D8, D1, D7 (Hot Spare memory bank
for four-way interleaving)
D4, D10, D3, D9
D6, D12, D5, D11
Chapter 2. Installing options
13

Advertisement

Table of Contents
loading

Table of Contents