Panasonic SA-HT822VP Service Manual page 46

Dvd/vhs home theater sound system
Hide thumbs Also See for SA-HT822VP:
Table of Contents

Advertisement

http://202.224.189.178/~sgml/viewing/SA-HT822VP/ALL/SVC/s1001010000.html
Display
U11
Detection of head clogging-ups
U30
Remote controller mode error
H01
No initialization of cylinder due to no loading(Cylinder, driving circuit failure, etc.)
H02
No capstan FG at load position(Capstan, driving circuit failure, etc.)
F03
Mechanism locking not because of unloading, cassette up* Displayed when detected twice
consecutively.
F04
Mechanism locking due to unloading* Displayed when detected twice consecutively.
F05
No S-reel pulse due to unloading(S-reel system, capstan system failure)
F06
Mechanism locking due to cassette up
F07
Recording circuit operation failure during REC operation
F08
Recording circuit operation failure not during REC operation
F15
No capstan FG when cassette is loaded(Capstan system, S-reel system failure)
H16
Cylinder lock detected during normal rotation
H17
S-reel lock detected during normal running
H18
T-reel lock detected during normal running
H80
EJECT mode when an error is detected
F2*
Error during PG automatic adjustment
TOP PREVIOUS NEXT
http://202.224.189.178/~sgml/viewing/SA-HT822VP/ALL/SVC/s1001010000.html (2 of 2)9/3/2004 9:43:12 AM
Meaning
Automatic display Memory
O
O
O
X
O
O
O
O
O
O
O
O
X
O
O
O
O
O
O
O
X
O
X
O
O
O
O
O
X
O
O
O

Advertisement

Table of Contents
loading

Table of Contents