NEC INTELLIGENT L2 SWITCH N8406-022A Application Manual page 88

1gb intelligent l2 switch
Hide thumbs Also See for INTELLIGENT L2 SWITCH N8406-022A:
Table of Contents

Advertisement

Configuring UFD on Switch 2 (AOS CLI example)
1.
Create a trunk group of uplink ports (20-24) to monitor. First you must set each port to full duplex mode.
>> Main# /cfg/port 20/gig/mode full
>> Main# /cfg/port 22/gig/mode full
>> Main# /cfg/trunk 2
>> Trunk group 2# ena
>> Trunk group 2# add 20
>> Trunk group 2# add 22
2.
Assign the trunk group to be monitored for communication failure.
>> Main# /cfg/ufd/fdp 1/ena
>> FDP# ltm
>> Failover Link to Monitor# addtrnk 2
3.
Assign downlink ports (1-16) to disable when an uplink failure occurs.
>> Main# /cfg/ufd/fdp 1/ltd
>> Failover Link to Disable# addport 1
>> Failover Link to Disable# addport 2
4.
Turn UFD on.
>> Main# /cfg/ufd/on
>> Uplink Failure Detection# apply (Make your changes active)
>> Uplink Failure Detection# save
When a link failure or Spanning Tree blocking occurs on trunk group 2, Switch 2 disables port 1 and port 2.
Configuring Uplink Failure Detection (BBI example)
1.
Configure Uplink Failure Detection.
a.
Click the Configure context button.
b.
Open the Switch folder, and select Uplink Failure Detection (click the underlined text, not the folder).
Open
Select
c.
Turn Uplink Failure Detection on, and then select FDP 1.
(Set port 20 to full duplex)
(Set port 22 to full duplex)
(Create trunk group 2)
(Enable trunk group 2)
(Add port 20 to trunk group 2)
(Add port 22 to trunk group 2)
(Enable Failure Detection Pair 1)
(Select Link to Monitor menu)
(Monitor trunk group 2)
(Select Link to Disable menu)
(Add port 1 as a Link to Disable)
(Add port 2 as a Link to Disable)
(Turn Uplink Failure Detection on)
(Save for restore after reboot)
High availability 88

Advertisement

Table of Contents
loading

Table of Contents