Emergency Drain - AEG L 87485 FL User Manual

Hide thumbs Also See for L 87485 FL:
Table of Contents

Advertisement

1
THE INLET HOSE FILTER AND
THE VALVE FILTER
It could be necessary to clean the filters
when:
• The appliance does not fill with wa-
ter.
• The appliance fills with the water for
a long time.
To clean the water inlet filters:
35°

EMERGENCY DRAIN

Because of a malfunction, the appliance
cannot drain the water.
If this occurs, do steps (1) through (6) of
'To clean the drain pump'.
2
45°
9. Clean the filter under the water tap
and put it back in the pump into the
special guides.
10
Make sure that you tighten correctly
.
the filter to prevent leakages.
11
Put the flap back and close the
.
drain pump door.
• The indicator of button
and the display shows the related
alarm. Refer to 'Trouble shooter and
service'.
WARNING!
Disconnect the mains plug from
the mains socket.
1. Close the water tap.
2. Remove the water inlet hose from
the water tap.
3. Clean the filter in the inlet hose with
a stiff brush.
4. Remove the inlet hose behind the
appliance.
5. Clean the filter in the valve with a
stiff brush or a towel.
6. Install again the inlet hose. Make
sure that the couplings are tight to
prevent leakages.
7. Open the water tap.
If necessary, clean the pump.
Put the drainage duct back and close
the drain pump flap.
ENGLISH