Thermostat Wiring Guide - International comfort products C9MVX Installation Instructions Manual

90+ two-stage & two-stage, variable category iv, gas furnace
Table of Contents

Advertisement

Thermostat Wiring Guide

1. These diagrams are for reference. See thermostat
wiring instructions for specific terminal assignments,
connections or operation.
2. Humidifier/humidistat is optional and not included
with the furnace.
3. Dehumidify feature (MPV & MVX models only) requires
thermostat with DEHUM feature or a separate dehumi-
distat to get the dehumidification operation. Dehumidis-
tat is optional and not included with the furnace.
4. Underlined terminal indicates intended use for multi-
ple function terminals.
5. TSIB terminals only available on MPV & MVX models.
6. Two--stage Air Conditioning or two--stage Heat Pump
capability only available with MPV & MVX models.
7. W2 furnace operation is from furnace control algo-
rithm SW1 DIP switch #3 (TT) set to OFF. Furnace
runs in Low Heat for 12 minutes then switches to High
Heat if heating call still exists.
HUM and DEHUM Terminal available from Thermostat. Humidifier Wiring (*9MPT, *9MPV, *9MVX)
Figure 50
Models and Dehumidify Wiring (*9MPV & *9MVX Models only)
440 01 2024 04
TSIB
NO CONNECTION
NO CONNECTION
TWO-STAGE or VS
FURNACE
CONTROL
SINGLE-STAGE
THERMOSTAT
W
Y
G
R
NOTE 3, 9, 10
DEHUM
C
HUM
Specifications are subject to change without notice.
8. 24V HUM terminal on furnace control is used to power
a humidifier (on call for heat and pressure switch
closed) if no HUM thermostat option is available.
9. DEHUM provides a 20% reduction in airflow (when Y1
or Y1 + Y2 is energized) when the furnace control DE-
HUM terminal is energized with 24V.
10. If no DEHUM thermostat option is available, a dehu-
midistat that has closed contacts on a call for dehu-
midify may be used
11. O provides a 10% reduction in airflow when Y1 or Y1 +
Y2 is energized and O is NOT energized. (J2 jumper
on TSIB must be in HP COMFORT position to get this
function. AC/HP EFFICIENCY position results in no
reduction of airflow for Y1 or Y1 + Y2 calls regardless
of O being energized or not.)
12. For Heat Pump/Furnace systems, refer to Fossil Fuel
Kit or Dual Fuel Thermostat Installation Instructions
for wiring.
NOTE 5
Y1
O
NOTE 11
W2
NOTE 7
SINGLE-STAGE
W1
AIR CONDITIONER
Y/Y2
G
R
DEHUM
C
OM
24V HUM
OPTIONAL
HUMIDIFIER
24V in
COM
NOTE 2
Y
C
53